![Patton electronics ForeFront 2616RC Скачать руководство пользователя страница 166](http://html2.mh-extra.com/html/patton-electronics/forefront-2616rc/forefront-2616rc_administrators-reference-manual_4061756166.webp)
PPP-IPCP Chassis Management Channel
166
Models 2616RC, 3096RC & 3196RC Admin Reference Guide
11 • In-band management
Figure 98. Defined In-Band Management Channels
Click on the
Modify Management Channels…
link. You are now able to select
ppp-bcp(2)
in the
Protocol
Type
column. Then click on
Modify
button in the
Action
column.
2.
We will now create the other end of the BCP PPP link on the 3096RC which is named
to2616RC
. Note
that the IP address is the same as the IP address of the 3096RC. Also, the Tx port is the same as the RX
port which we configured above. Similarly with the Rx port. One important point is that the management
channel is selected as the default gateway.
Figure 99. Define an H.110 Management Channel
3.
The
Protocol Type
must also be changed to BCP, ppp-bcp(2), in the same manner as was done in step
1
.
4.
After the bridged PPP link is
UP
, the web page will resemble
figure 100
on the 2616RC.
Figure 100. Defined In-Band Management Channels