4 • Getting started with the SmartNode
Model 4520 & 4110 Series Getting Started Guide
50
Bootloader
Note
With the Bootloader, only the Ethernet interface 0/0 is available. The Boot-
loader applies the IP address, subnet mask, and default gateway that were last
configured by the Bootloader itself or by another application (e.g. Smart-
Ware). If an application configured the Ethernet interface 0/0 to use DHCP,
the Bootloader will also use DHCP to learn the interface configuration. It
can receive and apply the IP address, subnet mask, default gateway, and
default (TFTP) server (transmitted as basic DHCP information ‘Next server
IP address’).
Note
This procedure does not download the respective CLI description file.
Download it after starting up SmartWare with the following command:
copy tftp://<tftp_server_address>/<server path>/b1 flash:
Example:
Downloading and storing a new application image (SmartWare)
RedBoot> ip -l 172.16.40.98/19
RedBoot> ip -g 172.16.32.1
RedBoot> ping -h 172.16.32.100
Network PING - from 172.16.40.98 to 172.16.32.100
..........PING - received 10 of 10 expected
RedBoot> load -r -v -h 172.16.32.100 -b 0x1800100 /Sn4xxx/image.bin
Using default protocol (TFTP)
-
Raw file loaded 0x01800100-0x0199ca6b, 1689964 bytes, assumed entry at 0x01800100
RedBoot> fis delete -n 1
Delete image 1 - continue (y/n)? y
... Erase from 0x60030000-0x601cc974: ..........................
RedBoot> fis create
Use address 0x01800100, size 1684402 ? - continue (y/n)? y
... Erase from 0x60030000-0x601cb3ba: ..........................
... Program from 0x00011eec-0x00011ef4 at 0x60030000: .
... Program from 0x01800100-0x0199b4b2 at 0x60030008: ..........................
... Program from 0x00011eec-0x00011ef4 at 0x60030000: .
Image successfully written to flash
RedBoot> fis list -l
Id Address Length State Description
Entry Load Addr Version
--------------------------------------------------------------------
1 0x60030000 1693438 valid SmartWare R2.10 BUILD28015
0x01800100 0x01800100 V2.10
RedBoot> go
Starting 'SmartWare R2.10 BUILD28015' at 0x01800100 via 0x01800100
8
RedBoot> go
Starts the application image that was down-
loaded into the volatile memory (RAM).
Step
Command
Purpose
Содержание 4520
Страница 6: ...Contents Model 4520 4110 Series Getting Started Guide 6...
Страница 12: ...About this guide Model 4520 4110 Series Getting Started Guide 12...
Страница 30: ...2 Applications overview Model 4520 4110 Series Getting Started Guide 30 Applications for SmartNode 4520 Series...
Страница 42: ...3 Hardware installation Model 4520 4110 Series Getting Started Guide 42 Installing the gateway router...
Страница 52: ...4 Getting started with the SmartNode Model 4520 4110 Series Getting Started Guide 52 Additional information...
Страница 53: ...53 Chapter 5 LEDs status and monitoring Chapter contents Status LEDs 54...
Страница 80: ...D Port pin outs Model 4520 4110 Series Getting Started Guide 80 FXO port...
Страница 81: ...81 Appendix E SmartNode 4110 Series factory configuration Chapter contents Introduction 82...
Страница 83: ...83 Appendix F SmartNode 4520 Series factory configuration Chapter contents Introduction 84...
Страница 85: ...85 Appendix G Installation checklist Chapter contents Introduction 86...