2.3  SUPPORTED APPLICATIONS

The Model 2500RC Series includes three units: the Model 2500RC

All-Rate CSU/DSU, the Model 2510RC Switched 56 CSU/DSU and the
Model 2520RC All-Rate/Switched 56 CSU/DSU.  Depending upon the
unit  selected, the Mode 2500RC Series supports three distinct modes
of operation.  These are outlined in the descriptions and table below:

Dedicated DDS/Clear Channel Operation (Models 2500RC, 2520RC)

The unit can be easily configured for dedicated DDS/Clear Channel

operation by means of the dip switches on the bottom of the enclosure,
or by means of the software control port.  Set the Line Rate to match
the rate of service to which you subscribe.  Set the Mode switches for
Network Clocking.  The Rate Converter and the Data Format options
should be set as required for your application.  The remaining options
may need to be set depending on your terminal equipment and your
application.

Switched-56 Operation (Models 2510RC, 2520RC)

The unit can be used in Switched 56 applications.  Set the Line

Rate to 56 Kbps.  Set the Mode switches for Switched 56, and enable
Force RTS and Circuit Assurance.  Dial or store a number using the
control port.  The Rate Converter and the Data Format options should
be set as required for your application.  The remaining options may
need to be set depending on your terminal equipment and your
application.

Campus Area Short Haul Operation (Models 2500RC, 2520RC)

The unit can also be used for campus area point-to-point short-haul

applications on private twisted-pair wires.  Set the Line Rates the same
on both units.  Set the Mode switch for the appropriate Transmit Clock
Mode for your application.  Internal, External and Looped Clock Modes
are available.  Set the remaining options as needed by your terminal
equipment or your application.

6

2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions arise during
installation or use of the unit, contact Patton Electronics Technical
Support:

(301) 975-1007

;

http://www.patton.com

; or,

[email protected]

.

2.1  PRODUCT FEATURES

•  Operates over 4-wire dedicated digital lines

•  Supports rates of 56 Kbps and 64 Kbps and all sub rates

•  Supports Switched 56 dialing

•  Both RS-232 and V.35 rear interface cards available

•  Features V.52 and V.54 compliant tests

•  Nine easy-to-read LED indicators to monitor data signals

•  Internal, external or received loopback clocking

•  AT&T 62310 compliant

•  Can be used as a high speed modem for private twisted pair

•  Fits in Patton’s rack chassis and Cluster Boxes

•  Made in the USA

2.2  GENERAL PRODUCT DESCRIPTION

The Model 2500RC Series CSU/DSUs 

operate either

synchronously or asynchronously over 4-wire circuits up to 64 Kbps.
Rate conversion allows operation with a variety of DTE devices.
Diagnostics include V.54 and V.52 loopback tests, as well as CSU
loops.  Configuration is accomplished by either internal DIP switches or
RS-232 software switches (user provides terminal).  Nine easy-to-read
function card LED indicators monitor data and control signals.  Two rear
interface cards are available:  DB-25 and RJ-48 or M/34 and RJ-48.

The Model 2500RC Series is AT&T compliant and  supports DDS,

Switched 56, Clear Channel 64 and other digital services available from
major service providers including AT&T, Sprint and MCI.  Dedicated
models can also be used as a high speed modem for private twisted
pair.  The Model 2500RC Series is available in standalone or in rack-
card versions (only rack card versions are covered in this manual).

5

MODEL 2500RC SERIES APPLICATIONS

2500RC

2510RC

2520RC

Line Rate Switches

All line rates

56 Kbps only

All line rates

Supported

Supported

Mode Switches

Supports all modes Switched 56 only

All modes

except Sw-56

Supported

Not Supported

Supported

Supported

Dialing
Commands

Содержание 2500RC

Страница 1: ...ls 2500RC 2510RC and 2520RC All Rate CSU DSU Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2500RC D Doc 099011U Rev E Revised 1 23 08 C E R T I F...

Страница 2: ......

Страница 3: ...etalized connector and configure the rear card as shown in section 3 3 of this manual 1 1 RADIO AND TV INTERFERENCE The Model 2500 Series generates and uses radio frequency energy and if not installed...

Страница 4: ......

Страница 5: ...er This number may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com Notice Packages received without an RMA number will not be accepted Patt...

Страница 6: ......

Страница 7: ...els 2510RC 2520RC The unit can be used in Switched 56 applications Set the Line Rate to 56 Kbps Set the Mode switches for Switched 56 and enable Force RTS and Circuit Assurance Dial or store a number...

Страница 8: ......

Страница 9: ...n On 2 4 Kbps On On Off 4 8 Kbps On Off On 9 6 Kbps On Off Off 19 2 Kbps Off On On 56 Kbps Off On Off 64 Kbps Off Off Off Force configuration pointer to default to Hardware Switches See Section 3 2 Fo...

Страница 10: ......

Страница 11: ...Loop 3 1 2 Switch Set S2 The configuration switches on switch S2 control the Rate Adapter DTE Rate Clock Mode Anti Stream Timer and RTS CTS Delay The table below shows factory default settings for Sw...

Страница 12: ......

Страница 13: ...Various Line Rates S2 8 CTS Delay 56 19 2 9 6 4 8 2 4 Off Normal 0 3 0 9 1 9 3 8 7 5 On Extended 1 3 3 8 7 5 15 30 3 1 3 Setting the Reversible Interface Driver Board The Model 2500RC Series supports...

Страница 14: ......

Страница 15: ...a time The Model 2500RC Series Main Menu should then display on the terminal screen see below 3 2 2 Using the Software Menu System The Model 2500RC Series Menu System operates as follows 1 All select...

Страница 16: ......

Страница 17: ...interface at a lower rate To do this set the line rate to 56 or 64 Kbps Then set the DTE Speed as required Software Switch Menu option 7 Circuit Assurance Choosing option 2 in the Software Switch Menu...

Страница 18: ......

Страница 19: ...provided the DTE equipment is configured to transmit two stop bits The extra stop bit reduces the DTE s effective data rate to allow synchronization with the 56 kbps line speed Set the Model 2500RC S...

Страница 20: ......

Страница 21: ...bits DTE Loop Control Choosing option 8 in the Software Switch Menu takes you to the DTE Loop Control Menu below The local and remote loopbacks on the Model 2500RC Series can be controlled from the DT...

Страница 22: ......

Страница 23: ...Choosing option b in the Software Switch Menu takes you to the RTS CTS Delay Menu below This option lets you set the RTS CTS turn on delay to Normal or Extended The delay interval decreases as the lin...

Страница 24: ......

Страница 25: ...is a detailed description of each strap s function DTE Shield Pin 1 FRGND JB3 In the connected position this strap links DB 25 pin 1 frame ground In the open position pin 1 is lifted from frame groun...

Страница 26: ......

Страница 27: ...ed conveniently 4 1 1 The Rack Power Supply The power supply included in the Model 1000R16 rack uses the same mid plane architecture as the modem cards The front card of the power supply slides in fro...

Страница 28: ......

Страница 29: ...status of communication Figure 12 below shows the location of the LEDs on the Model 2500RC Series front panel Note also the location of the test mode switches and RS 232 control port used in Switched...

Страница 30: ......

Страница 31: ...itches go to the Main Menu and select item 2 Read Configuration This will take you to the Read Configuration Menu below In the Read Configuration Menu you may select item 1 to read the hardware switch...

Страница 32: ......

Страница 33: ...l Line Loop Menu see below To activate LAL select item 1 LAL Test Procedure Once LAL is activated the Model 2500RC Series transmit output is connected to its own receiver The Test LED should be lit Fo...

Страница 34: ......

Страница 35: ...out making visits to a customer s premises CSU Loop The CSU Loop is activated when the central office reverses the DC sealing current that flows between the TX pair and the RX pair In this case the Mo...

Страница 36: ......

Страница 37: ...eries automatically dials this number when the DTE raises the DTR lead When you issue this command the Model 2500RC Series responds with this prompt Enter up to 12 digits without hyphens or other alph...

Страница 38: ......

Страница 39: ...S point to point or multipoint campus area point to point Indicators LED indicators for TD RD CTS CD DTR No Signal Out of Service Error and Test Mode Diagnostics V 54 compliant local and remote loopba...

Страница 40: ......

Страница 41: ...le 1000RPSM 2 120 240V Front Power Supply Module 1000RPEM DC DC Rear Power Entry Module 1000RPSM 48A 48V Front Power Supply Module 1000RPEM V 120 240V CE Compliant Rear Power Entry Module 1000RPSM V 1...

Страница 42: ......

Страница 43: ...rame Ground 2 TD 3 RD 4 RTS 5 CTS 6 DSR 7 SGND Signal Ground 8 CD 15 TC 17 RC 18 LL Local Loop 20 DTR 21 RL Remote Loop 24 XTC 25 TM Test Mode CONTROL PORT INTERFACE 8 Position modular connector compl...

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ...n any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales patton com Support E mail sup...

Отзывы: