manualshive.com logo in svg
background image

1.  Open the unit by gently inserting a screwdriver between the

DB-25 connector and the lip of the plastic case (see below).
You don't have to worry about breaking the plastic, but be
careful not to bend the D-sub connector.

Having opened the unit's case, you will find the terminal block
mounted at the rear of the PC board (see below).  The
terminals are labled “S” for “signal” and “G” for “ground“.

5

2.  Strip the outer insulation from the twisted pairs about one inch

from the end.  

3.  Strip back the insulation on each of the 2 wires about .25”.

4.  Insert the two wire data line to the center (signal) and shield

(ground) terminal posts, then tighten the screws.  Depending
on version, terminal post locations may vary.

NOTE:

 

Be sure that all cabling between the short range

modems is straight through:  

SIGNAL (S) (S) SIGNAL

GROUND (G) (G) GROUND

6

DCE/DTE

Switch

Surge

Suppressors
(1002S only)

Terminal

Block

Содержание 1002S

Страница 1: ...ODEL 1002 and 1002S Asynchronous 2 Wire Coax Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1002 C Doc 050011UC Revised 4 28 98 An ISO 9001 Cert...

Страница 2: ...ed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 1002 do...

Страница 3: ...of coax cable via female BNC The Model 1002S is a surge protected version of the Model 1002 that uses the latest in bi directional clamping transient suppressors to protect itself and connected equip...

Страница 4: ...rminals are labled S for signal and G for ground 5 2 Strip the outer insulation from the twisted pairs about one inch from the end 3 Strip back the insulation on each of the 2 wires about 25 4 Insert...

Страница 5: ...ase together yet 7 Insert one captive screw through a saddle washer and then insert the entire piece through the hole in the DB 25 end of the case Snap that side of the case closed Repeat on other sid...

Страница 6: ...or half duplex Transmit Level 0 dBm Control Signals DSR and DCD turn ON immediately after the terminal raises DTR CTS turns ON immediately after the terminal raises RTS Surge Protection Compliant with...

Страница 7: ...can affect the maximum distances obtainable at a particular site Use maximum distance figures as a general guidelin only APPENDIX C PATTON MODEL 1002 INTERFACE CONNECTIONS 11 12 1 FG Frame Ground 2 T...

Страница 8: ...APPENDIX D PATTON MODEL 1002 BLOCK DIAGRAM Copyright 1998 Patton Electronics Company All Rights Reserved 13...

Отзывы: