2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

• Full duplex operation on coax or a single twisted pair
• Data rates to 19,200 bps
•  Range to 2 miles (3.2 km)
•  No AC power or batteries required
•  Twisted pair connection via strain relief, RJ-11 or RJ-45
•  Surge protected (Model 1000S only)
•  Coax connection via female BNC (optional)
•  External DCE/DTE switch
•  Made in the USA

2.2  DESCRIPTION

The Model 1002 Asynchronous Short Range Modem

extends

RS-232 distances to 2 miles (3.2 km) over coax or a single
unconditioned twisted pair.  The small size of this unit enables use
where serial ports are very close together or are not easily accessible.
The Model 1002 incorporates innovative circuitry that lets it operate
without connection to AC power or batteries.  The necessary power for
operation is derived from the RS-232 input signals.

An external DCE/DTE switch allows easy connection of the Model

1002 to any device without opening the unit to re-configure.  Three
enclosure options allow termination of a single twisted pair via RJ-11,
RJ-45 or terminal blocks.  A unique strain relief prevents the twisted
pair from breaking or pulling loose.  An additional enclosure option
allows termination of coax cable via female BNC.

The Model 1002S is a surge protected version of the Model 1002

that uses the latest in bi-directional, clamping, transient suppressors to
protect itself and connected equipment against harmful transient
discharges.  For surge handling capability, the Model 1002S is
compliant with IEC 801.5 level 2, 1kV.

3

3.0  INSTALLATION

The  Patton Model 1002 is easy to install and should give you

years of trouble-free service.  You must have a PAIR of units to perform
an installation—one at each end of an unconditioned twisted pair or
coax cable.  The following instructions explain this procedure.

3.1  SETTING THE DTE/DCE SWITCH 

For your convenience, the Model 1002 has an externally

accessible DCE/DTE switch (see diagram below).  If the device
connected to the Model 1002 is a modem or multiplexer (or is wired like
one), set the DCE/DTE switch to “DTE”.  This means the Model 1002
will behave like Data Terminal Equipment and transmit data on pin 2.  

If the device connected to the Model 1002 is a PC, terminal or host

computer (or is wired like one), set the DCE/DTE switch to "DCE".  This
setting means the Model 1002 will behave like Data Communications
Equipment and transmit data on pin 3.

3.2  CONNECTING THE LINE SIDE 

Depending upon the type of unit, the Model 1002 connects to the

line side via single twisted pair (terminal block, RJ-11, RJ-45) or coax
(BNC).  Follow the appropriate instruction set for the type of unit you
have.

3.2.1  Connection Using the Terminal Block 

Terminal blocks are used to connect a single pair of bare wires to

the Model 1002.  The following instructions will tell you how to open the
case, connect the bare wires and fasten the strain relief collar in place.

4

DCE DTE

Содержание 1002S

Страница 1: ...ODEL 1002 and 1002S Asynchronous 2 Wire Coax Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1002 C Doc 050011UC Revised 4 28 98 An ISO 9001 Cert...

Страница 2: ...ed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 1002 do...

Страница 3: ...of coax cable via female BNC The Model 1002S is a surge protected version of the Model 1002 that uses the latest in bi directional clamping transient suppressors to protect itself and connected equip...

Страница 4: ...rminals are labled S for signal and G for ground 5 2 Strip the outer insulation from the twisted pairs about one inch from the end 3 Strip back the insulation on each of the 2 wires about 25 4 Insert...

Страница 5: ...ase together yet 7 Insert one captive screw through a saddle washer and then insert the entire piece through the hole in the DB 25 end of the case Snap that side of the case closed Repeat on other sid...

Страница 6: ...or half duplex Transmit Level 0 dBm Control Signals DSR and DCD turn ON immediately after the terminal raises DTR CTS turns ON immediately after the terminal raises RTS Surge Protection Compliant with...

Страница 7: ...can affect the maximum distances obtainable at a particular site Use maximum distance figures as a general guidelin only APPENDIX C PATTON MODEL 1002 INTERFACE CONNECTIONS 11 12 1 FG Frame Ground 2 T...

Страница 8: ...APPENDIX D PATTON MODEL 1002 BLOCK DIAGRAM Copyright 1998 Patton Electronics Company All Rights Reserved 13...

Отзывы: