19
9. Replace the orifice fittings into the valve.
11, Adjust oven burner air shutter from half open
to full open. then screw in, ensure fix well
13.2, Regulator convert for
60”range
change the part from R500 Nat 3”-6”W.C to R500 LP 11”W.C.
14. Continue with installation.
15. Attach gas conversion label on appliance, the position below.
Gas conversion label
The position for gas conversion
16. Completed gas conversion.
Pictured is the plastic insert. Pull off insert
from octagon cap and reverse the plastic
insert position so that the L.P. position is
attached to the octagon cap head.
13.1,
Regulator convert for 24”range &36”range
and 48”range series
only
Before installing the included convertible
regulator,
unscrew
the
octagon
cap.
You
can
read (NAT) on the
plastic insert attached to the head of the cap; flip it
over and snap back in place.
L.P. Position of
insert. Regulator
is now converted
to L.P.
10, Screw out oven burner air
shutter screw
12, Replace orifice and oven
burner