Operation

6

V Offset (voltage offset):

 The default voltage offset in the Voltage Offset display is 

0.00 V. Use the Voltage Adjust knob and the Resolution Buttons to increase or 
decrease the DC voltage. Any waveform can be offset up or down with a DC voltage 
ranging from -10 V to +10 V, provided the peak voltage does not exceed 10 V. 

V Limit (voltage limit):

 The default maximum voltage in the Voltage Limit display 

is 10.00 V. Use the Voltage Adjust knob and the Resolution Selection buttons to 
change the maximum voltage from 10.00 V to another voltage. The minimum voltage 
is 0.00 V. 

I Limit (current limit):

 The default maximum current in the Current Limit display is 

1.50 A. Turn the Voltage Adjust knob to change the maximum current from 1.50 A to 
1.10 A or to 0.55 A. Press the Voltage Adjust knob as if it were a button to select the 
current limit. Setting the maximum current is useful when there needs to be a limit to 
the current applied to a circuit. This is a safety feature to protect against short circuit 
overload. 

Backlight:

 The default backlight setting is “High”. Use the Voltage Adjust knob to 

select the menu choice. Press the Voltage Adjust knob as if it were a button to toggle 
(switch) to the other choice: “Low”. The Low setting is useful when the Function 
Generator is in a darkened environment. 

Sweep:

 Turn the Voltage Adjust knob so the pointer is next to Sweep and then press 

the knob as if it were a button to select the choice. The default setting is “Off”.

The Sweep menu options offer several ways to tailor the output signal for specific 
needs. The Sweep function is set up so that the output signal begins at a specific fre-
quency (Initial) and ends at another specific frequency (Final). The ‘sweep’ between 
frequencies can be set to last for a certain time (Duration), and the step frequency 
(Step) can also be set for a specific amount.. 

The Sweep function can be set to one of the following: 

Off: The default setting.

Press the MENU button or the 
Voltage Adjust knob to return 
to the MENU choices. 

Press the MENU button again 
to return to the screen before 
the MENU button was 
pressed the first time.

Voltage 

Offset 

display

Voltage 

Limit 

display

Current 

Limit 

display

NOTE: As the current approaches 
the limit, “Overcurrent” will be dis-
played at the bottom of the LCD. The 
“Overcurrent” warning will be dis-
played at approximately 1.2 A for the 
1.50 A limit, 1.0 A for the 1.10 A limit, 
and 0.5 A for the 0.55 A limit.

Backlight Low

Sweep options

Содержание PI-8127

Страница 1: ...ment See the PASCO Catalog for details Mechanical Wave Driver SF 9324 Open Speaker WA 9900 AC DC Electronics Laboratory EM 8656 RLC Circuit Board CI 6512 Output jacks 4 mm Resolution Selection buttons Output Standby button Power button Liquid Crystal Display LCD Frequency Adjust knob and Range Selection button Waveform Selection button Menu button Voltage Adjust knob and Menu Selection button ...

Страница 2: ...Voltage Maximum The maximum current or maximum voltage can be set using a menu This is useful when the voltage applied to a circuit needs to be limited The LCD displays the output voltage and current Offset Voltage Any waveform can be offset up or down with a DC voltage ranging from 10 V to 10 V provided the peak voltage does not exceed 10 V Frequency Sweep Sweep between two frequencies at a selec...

Страница 3: ...sible to have zero frequency To lower the frequency press the right hand Resolution Selection button to move the underline to the right 1 000 kHz and then turn the Frequency Adjust knob counterclockwise one click to decrease the frequency to 0 900 kHz Resolution Selection Use the Resolution Selection buttons beneath the Frequency Adjust knob to change the active underlined digit in the display Pus...

Страница 4: ...part of the LCD turn the Frequency Adjust knob one click to the left or right Waveforms Press the WAVEFORM button to open the first waveform menu The menu shows five choices Sine Square Triangle Positive Ramp and Negative Ramp with the pointer at Sine Turn the Voltage Adjust knob one click to the left counterclock wise to move the pointer from Sine to Square Press the Voltage Adjust knob as if it ...

Страница 5: ...n a modulated Mod waveform is selected the signal produced by the Function Generator will be multiplied by the signal from the external input Change the frequency of the Function Generator s signal with the Frequency Adjust knob Adjust the percent modulation with the Voltage Adjust knob The formula for the percent modulation is based on the amplitudes of the peak P and the trough T of the modulate...

Страница 6: ... menu choice Press the Voltage Adjust knob as if it were a button to toggle switch to the other choice Low The Low setting is useful when the Function Generator is in a darkened environment Sweep Turn the Voltage Adjust knob so the pointer is next to Sweep and then press the knob as if it were a button to select the choice The default setting is Off The Sweep menu options offer several ways to tai...

Страница 7: ...is 1 second and the maximum is 9999 seconds 2 h 46 min 39 s Press the Voltage Adjust knob as if it were a button to return to the menu of Sweep options Step The default step frequency is None This means that the default frequency sweep will be continuous from the initial to the final frequency As with the initial fre quency use the Voltage Adjust knob to select Step and press the knob as if it wer...

Страница 8: ...ted for experiment in waves and acoustics Drive a speaker or several speakers with the Function Generator Accurately set the frequency to any level in the acoustic range or beyond This makes it particularly con venient for experiments such as measuring the speed of sound observing the interfer ence and diffraction of sound waves and investigating acoustic resonance in a cavity Use the Function Gen...

Страница 9: ...ons that vary by country and region It is your responsibility to recycle your electronic equipment per your local environmental laws and regulations to ensure that it will be recycled in a manner that protects human health and the environment To find out where you can drop off your waste equipment for recycling please contact your local waste recycle disposal service or the place where you purchas...

Отзывы: