V e n t u r i   A p p a r a t u s

0 1 2 -0 9 4 8 6B   A p p e n d i x   B :   F l u i d   S u p p l y   a n d   F l o w   R a t e  

10

other end of the spirometer tubing (see Figure 5 or 7). Assemble the mouthpiece and 
spirometer handle, and connect the spirometer to your PASPORT interface.

The spirometer automatically calibrates itself every time you start data collection. 
During the first few seconds of data collection, it must remain still and away from air 
currents. A red WAIT light and green READY light illuminate to indicate when the 
sensor is calibrating and when it is ready to measure air flow. Start data collection (by 
pressing or clicking the Start button) with the air supply off, and wait until the spirom-
eter is ready before turning the air supply on.

2

 

Water

Water Supply

Set up the apparatus with at least 1.5 m of vertical drop from 
the top surface of the water reservoir to the bottom of the drain 
tube. Elevate the reservoir above your lab bench and put the 
catch basin on the floor (see Figure 8).

Cut the water tubing into two pieces of suitable length. Con-
nect one piece of tubing to the outflow port of the apparatus 
and run it over the side of the lab bench into the catch basin. 
Secure the tubing so water will not spill onto the floor. Place 
both hose clamps on the outflow tubing. Close one of the clams 
partially to regulate the flow rate. Close the other clamp com-
pletely; you will open and close this clamp to start and stop 
water flow.

Run the other piece of tubing from the reservoir to the inflow 
port of the apparatus. Connect the tubing to the bottom hose 
fitting of the model ME-8594 Water Reservoir, or (if you are 
using a container without a hose fitting) set up the tubing as a 
siphon.

Note: Observe the correct direction of water flow through the apparatus indicated in Figure 2.

Connect the Quad Pressure Sensor if it is not already connected (see page 5).

Important

: Do not allow water to enter the sensor’s pressure ports. Connect the quad pressure 

sensor to the apparatus before filling it with water. Once water is in the apparatus, do not discon-
nect the sensor; otherwise water will flow through the pressure tubes. 

Fill the reservoir with water. (If you are using the tubing as a siphon, fill it and the 
apparatus with water as well, or use suction to draw water into them.) 

Included Parts Required

Fluid tubing (at least 1.5 m)

2 restriction clamps

Other Parts Required or Recommended

Part Number

Water Reservoir (or other container of at least 1 liter)

ME-8594

Container to catch water

Equipment to elevate and secure reservoir:

Table Clamp

ME-9472

120 cm rod

ME-8741

2 Three-finger clamps

SE-9445

2

For more information on 

the spirometer, see the 
instructions included with 
it (PASCO instruction 
sheet 012-08856).

 Figure 8: Setup for water

Reservoir

Quad Pressure 

Sensor

Clamp

Содержание ME-8598

Страница 1: ...Venturi Apparatus ME 8598 Instruction Manual 012 09486B 012 09486...

Страница 2: ...ts 4 Setup 5 Procedure 5 Analysis 5 Further Analysis 6 Clean up 6 Storage 6 Appendix A Quad Pressure Calibration 7 DataStudio 7 Xplorer GLX Standalone Mode 7 Appendix B Fluid Supply and Flow Rate Meas...

Страница 3: ...r container ME 8594 Required Equipment Container to catch water Quad Pressure Sensor PS 2164 Table Clamp ME 9472 PASPORT Interface 5 See PASCO catalog or www pasco com 120 cm rod ME 8741 2 Three finge...

Страница 4: ...stance time and the cross sec tional area of the pipe The flow rate must be constant over the length of the pipe This relationship is known as the Continuity Equation and can be expressed as eq 1 R A0...

Страница 5: ...e pressure measurements on a graph display Obtain a few seconds worth of good data before stopping data collection and fluid flow Analysis 1 View your data on a graph of pressure versus time 2 Select...

Страница 6: ...in the venturi constriction Compare this to the actual pressure measured by the sensor P2 Further Analysis Repeat the analysis above for Points 2 3 and 4 Clean up 1 Allow the water reservoir to run em...

Страница 7: ...t the top of the Calibrate Sensors window select Quad Pressure Sensor 4 Select the Calibrate all similar measurements simulta neously option 5 Select the 1 Point Adjust Offset Only option 6 Click Read...

Страница 8: ...an air supply Almost any model will work but one that has a hose connection for blowing air out may be pref erable since it can push as well as suck air through the apparatus Air supplies designed for...

Страница 9: ...is method a Spirometer sensor measures the airflow rate Use the PASCO Spirometer sensor to measure airflow rate The Spirometer is primary designed for measuring airflow in and out of a person s lungs...

Страница 10: ...ially to regulate the flow rate Close the other clamp com pletely you will open and close this clamp to start and stop water flow Run the other piece of tubing from the reservoir to the inflow port of...

Страница 11: ...water drains It is not necessary to get good data over the entire range of water level since you will only need about 2 seconds worth of data Stop water flow and refill the reservoir Delete your test...

Страница 12: ...g the container from the sensor s hook see Figure 11 or Setup the force sensor on the floor with the Balance Stand and Pan and place the container on the pan 2 Position and secure the end of the outfl...

Страница 13: ...t of water has flowed through stop the stopwatch and close the clamp 4 Measure the volume of water that flowed out of or into the apparatus 5 Calculate the average flow rate eq 5 where V is the volume...

Страница 14: ...in their lab oratories and classrooms and are not sold for profit Reproduction under any other circumstances without the written consent of PASCO scientific is prohibited Trademarks PASCO PASCO scient...

Страница 15: ...ation Wash contacted areas with soap and water Ingestion If ingested drink 2 glasses of water seek prompt medical attention and Induce vomiting IV Protective Equipment For Handling Eyes Safety Goggles...

Страница 16: ...hysical Properties Vapor Pressure N A Vapor Density N A Soluble in Water Negligible Specific Gravity les than 1 0 Boiling Point 700 Volatile Organic Compound N A Appearance Semi solid Amber Color No o...

Отзывы: