Respiration Rate Sensor

012-07034A

6

Studying Chemical Reactions by Monitoring

Pressure

Many chemical reactions produce gases that can cause

an increase in pressure in a sealed container. The

pressure change can be used to monitor the rate of the

reaction.

Other

PASCO scientific also produces an Absolute Pressure

Sensor (Model CI-6532A), a Differential Pressure

Sensor (Model CI-6533) and a Barometer (Model CI-

6531A). The Absolute Pressure Sensor has a range

from 0 to 700 kiloPascals. The Differential Pressure

Sensor is similar to the CI-6532A, except that both

ports of the transducer are open to the atmosphere. It

is designed for experiments where pressure differs

from one part of the apparatus to another, such as in a

Venturi tube or for a demonstration of Bernoulli’s

principle. The Barometer has a range from 800 to

1100 milliBar (24 to 32 inches of mercury). It is

designed to be a reliable, accurate pressure sensor

for weather studies. It is temperature compensated

and has a voltage regulator, so changes in

temperature or changes in the computer’s power

supply will not interfere with the data.

Note:  This instruction sheet was written assuming that

the user has a basic familiarity with

Science Workshop and has access to the User’s

Guide for Science Workshop. Users can gain basic

skills by working through the tutorial within

Science Workshop. Another useful resource is the

Quick Reference Card for Science Workshop.

DIN Connector Specifications

1: analog output (+), -10 to +10 V

2: analog output (-), signal ground

3: (no connection)

4: + 5 V DC power

5: power ground

6: +12 VDC power

7: -12 VDC power

8: (no connection)

Limited Warranty

PASCO scientific warrants the product to be free from

defects in materials and workmanship for a period of

one year from the date of shipment to the customer.

PASCO will repair or replace, at its option, any part of

the product which is deemed to be defective in

material or workmanship. The warranty does not cover

damage to the product caused by abuse or improper

use. Determination of whether a product failure is the

result of a manufacturing defect or improper use by

the customer shall be made solely by PASCO

scientific. Responsibility for the return of equipment

for warranty repair belongs to the customer.

Equipment must be properly packed to prevent

damage and shipped postage or freight prepaid.

(Damage caused by improper packing of the

equipment for return shipment will not be covered by

the warranty.) Shipping costs for returning the

equipment after repair will be paid by PASCO

scientific.

Address:

PASCO scientific

10101 Foothills Blvd.

Roseville, CA  95747-7100

Phone:

(916) 786-3800

FAX:

(916) 786-8905

email:

[email protected]

web:

www.pasco.com

10 k

Pa M

AX

DRY

 AIR

 ON

LY

PRE

SSU

RE P

ORT

 MA

TIN

G

CON

NEC

TOR

:

PAS

CO P

ART

 NO

. 640-0

21

1

4

3

5

2

6

7

8

Содержание CI-6534A

Страница 1: ...O computer interface The pressure sensor uses a 10 kiloPascal transducer This type of transducer has two ports The reference port of the transducer is inside the electronics box It is always open to the atmosphere and not available to the user The other port is connected to the atmosphere via the pressure port connector at the front of the pressure sensor unit It has a quick release style connecto...

Страница 2: ...tion Belt PASCO part no 003 05936 included in the CI 6535 Respiration Rate Sensor Heat Engine Gas Law Apparatus PASCO part no TD 8572 Extra parts are available as follows Item Part Number plastic syringe 699 084 polyurethane tubing 640 023 quick release connector 640 021 Respiration Belt 003 05936 Range and Resolution The range of the CI 6534A Low Pressure Sensor is between 0 and 10 kiloPascals Th...

Страница 3: ...ors into one end of the short piece of tubing Put the other end of the tubing over the tip on the end of the syringe Note You can lubricate the end of the barb to make it easier to put into the short piece of tubing Put a very small amount of silicon oil or saliva onto the barb and then wipe the barb with a cloth so there is only a thin layer of lubricant on the barb Align the quick release connec...

Страница 4: ...k and pile strips match each other The belt should be snug around the chest but not so tight that breathing is restricted See Figure s 6 and 7 Connecting the Belt to the Sensor Align the quick release connector on the end of one of the respiration belt s tubes with the pressure port connector at the front of the pressure sensor unit alignment hole 1 4 20 threaded connector Figure 5 Mounting connec...

Страница 5: ...gas is directly proportional to its absolute temperature Set up a sealed container of air by attaching the longer piece of plastic tubing to a stopper in a 125 mL Erlenmeyer flask Put a drop of glycerin on the bottom of one hole of a two hole rubber stopper Put the glass part of an eyedropper tip end up through one hole in the rubber stopper CAREFULLY put the end of the plastic tubing over the tip...

Страница 6: ...through the tutorial within Science Workshop Another useful resource is the Quick Reference Card for Science Workshop DIN Connector Specifications 1 analog output 10 to 10 V 2 analog output signal ground 3 no connection 4 5 V DC power 5 power ground 6 12 VDC power 7 12 VDC power 8 no connection Limited Warranty PASCO scientific warrants the product to be free from defects in materials and workmans...

Отзывы: