2.0 Product Description
The XTM 353S and 403S are complete
semiautomatic constant voltage DC arc welding
machines built to meet CE specifications. They
combine a constant voltage power source and a
constant speed wire feeder with a microcomputer-
based controller to form a reliable high-performance
welding system. A simple control scheme, consisting
of a range voltage and wire feed speed controls,
provides versatility with ease of use and accuracy.
Other features include separate wire feed unit for
remote operation, an integral gas cylinder mounting
undercarriage, an adjustable Argon flow regulator
with cylinder pressure gauge and inlet hose, a Parweld
MIG torch, and a 3.0m work cable with clamp.
Digital meters display the actual welding voltage and
amperage and the machine has additional controls for
adjustment of burn back and soft starting.
3.0 Technical Specifications
The XTM353S and 403S are a separate type machine
with the wire feed unit connected to the power supply
but a 5m interconnecting cable for use with 3 phase
400V supply.
Feature
XTM353S
XTM403S
I n p u t
voltage
400V
+/-
10%
400V
+/-
10%
Hz
50
50
Phases
3
3
C u r r e n t
Draw (A)
13
14
Fuse rating
(A)
16
25
O u t p u t
current (A)
50-250
60-350
OCV
18-36
20-45
L o a d
voltage
16.5-26.5
17-31.5
Feed speed
m/min
0.8-24
0.8-24
Feed motor
42V
42V
Wire drive
4 roll
4 roll
1
2 3 4
5
6
7
8
9
8
7
6
4 5
1
2
3
A
B
C
1
V
!
0
V
A
XTM 403S
V
V
9
11
12
14
15
WIRE
FEEDER
INTERCONNECTING PLUG
WIRE FEEDER
8A
CONTROL
CIRCUIT
AUX 230V 1P
V 3P -400V
8A
ISO/IEC 60974-1
3 ~50 Hz
U0= 20~42V
U1 = 400v
I max =23A
I eff =16A
IP 21S
Rohs Compliant
ENGLAND.
DY12 2TZ,
WORCESTERSHIRE,
LONG BANK BEWDLEY,
10
13