P
AGE
68
Er19
- Tried to run
1. Press the RUN/Hold key, then press and release the
profile with 0 segments
SCROLL key until oFF or CtrL are displayed then
press the DOWN key. This error occurs if a profile
number is selected in the Profile Continue mode for a
profile that has not been developed.
Er20
- Setpoint Error
1. Press the UP or DOWN key to change the setpoint to
a different value, then restore the needed setpoint.
2. Perform the CAL1 procedure as described in the
Calibration section (page 52).
Er21
- Pen Feedback
1. Perform the steps listed for “Pens do not operate”
Error
condition (page 63).
Er36
-Incorrect Crystal
1. Turn off the power to the instrument, wait 5 seconds,
For Digital Comm.
then turn the power on.
Er37
- Incorrect Micro.
1. Turn off the power to the instrument wait 5 seconds,
For Digital Comm.
then turn the power on.
Momentary Er70
-
1. Tried to communicate while unit was in a non-control
Controller unable to respond
mode.
within 250 milliseconds
Momentary Er71
-
1. The unit received a request before proper amount of
Byte received before the
time has elapsed since last request.
response was transmitted
Momentary Er72
-
1. Data received not valid, possible corruption on the
Incorrect Block check
comm link. Possible noise.
character received
Momentary Er73
-
1. Improper parity selection on the transmitting terminal.
Byte received with incorrect
parity
2. Incorrect baud rate.
3. Noise.
Содержание MRC 7700
Страница 11: ...PAGE 11 FIGURE 2 2 FIGURE 2 3 Inductive Load 0 5 mfd 1000V 220 ohms 115V 1 4W 230V 1W Inductive Load R C MOV AC...
Страница 27: ...PAGE 27 HyAo rSP rSPu rSPL SPuL HyCo SPLL AtFr Prnd dFF PFF Pout Pou PoL Cru C C B CrL P1EC P2EC D...
Страница 29: ...PAGE 29 rrH PPC PIA F Crt Coo Com Optional Con CbS CAd1 CAd2 PAPu...
Страница 50: ...PAGE 50 Curve A unstable Curve B stable Curve C continuously cycling ultimate PB and period A C B Period...