INSTRUCTION REF: IN172
ISSUE No. 1
DATE 30.10.09
Page 5 of 17
www.parry.co.uk
GAS CONNECTION
The size of the supply pipe should be no less than 1/2
” B.S.P. and an easily
accessible, hand operable gas isolation tap must be located within 1 metre of the
appliance.
Annual servicing by a competent engineer is essential to maintain safety and
prolong the life of the appliance. All gas appliances must be fitted by a competent
person, to gas safety regulations in force.
Before the appliance is commissioned the gas safety regulations require that all
connections on the gas line are tested for gas soundness between the gas
supply and appliance.
The parts protected by the manufacturer or agent, should not be adjusted by the
installer. All packing and protective film must be removed from the appliance
prior to commissioning.
The burner is fitted with a flame failure device and the gas control has an integral
piezo spark ignitor.