INSTRUCTION REF: IN172
ISSUE No. 1
DATE 30.10.09
Page 11 of 17
www.parry.co.uk
7.
Undo the 2 philips screws that attach the injector bracket to the burner.
Remove injector from the bracket and replace with the alternative gas
injector supplied in the conversion kit.
8.
Reverse steps 1
– 7
9.
Once the injector has been changed the pilot
must be adjusted to suit the alternate gas. To do
this remove bung on bottom of pilot assembly
see image.
10.
Using a screwdriver adjust pilot jet to obtain a
pilot flame blue in colour, and sufficiently large to
heat the thermocouple ensure there is no yellow
present in the flame.
11.
On completion test for soundness
When conversion is complete affix new data label and the appropriate gas label