INSTRUCTION REF: IN172
ISSUE No. 1
DATE 30.10.09
Page 4 of 17
www.parry.co.uk
INSTALLATION INSTRUCTIONS
ALL APPLIANCES MUST BE FITTED AND OR CONVERTED BY A
REGISTERED INSTALLER.
THE APPLIANCE MUST BE FITTED IN ACCORDANCE WITH CURRENT GAS
REGULATIONS, THE NATIONAL WATER REGULATIONS IN FORCE, AND IN
ACCORDANCE WITH EN 1717
INSTALLATION
Before installation check data plate on rear of unit to ensure appliance is suitable
for gas supply available.
During installation provision must be provided for combustion air to the appliance
through base and rear of appliance. This should not be blocked at any time.
This appliance should be installed with sufficient ventilation to prevent the
occurrence of unacceptable concentrations of substances harmful to health in the
room in which it is installed.
POSITIONING
The appliance must not be installed on or against combustible surfaces
–
minimum clearances must be :
Rear
150mm (6”)
Sides
150mm (6”)
Unit
to combustible material 1525mm (60”)
Ensure appliance is installed onto a level, non- combustible surface.
If the appliance is to be used in a mobile trailer we recommend that the unit is
fastened down to the work surface with the two fixing brackets that are supplied
with the unit.
All local fire regulations should be observed.
It is recommended that the appliance be sited below a ventilating hood preferably
of the extractor type incorporating a grease filter.