INSTALLATION INSTRUCTIONS 

 

ALL APPLIANCES MUST BE FITTED AND OR CONVERTED BY A 
REGISTERED INSTALLER.  
 
THE APPLIANCE MUST BE FITTED IN ACCORDANCE WITH CURRENT GAS 
REGULATIONS, THE NATIONAL WATER REGULATIONS IN FORCE, AND IN 
ACCORDANCE WITH EN 1717 
 
INSTALLATION 

Before installation check data plate on rear of unit to ensure appliance is suitable 
for gas supply available. 
 
During installation provision must be provided for combustion air to the appliance 
through base and rear of appliance. This should not be blocked at any time.  
 
This appliance should be installed with sufficient ventilation to prevent the 
occurrence of unacceptable concentrations of substances harmful to health in the 
room in which it is installed. 
 

POSITIONING 

The appliance must not be installed on or against combustible surfaces 

– 

minimum clearances must be : 

 

Rear  

150mm (6”) 

 

 

Sides 

150mm (6”) 

Unit 

to combustible material 1525mm (60”)  

Ensure appliance is installed onto a level, non- combustible surface. 
 
If the appliance is to be used in a mobile trailer we recommend that the unit is 
fastened down to the work surface with the two fixing brackets that are supplied 
with the unit. 

 

All local fire regulations should be observed. 
 
It is recommended that the appliance be sited below a ventilating hood preferably 
of the extractor type incorporating a grease filter. 
 

Содержание SGWB

Страница 1: ...INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS FAULT DIAGNOSTICS TECHNICAL DATA EXPLODED VIEW PARTS LIST WARRANTY INFORMATION Customer Information MODEL NUMBER ____________...

Страница 2: ...nd Safety at Work Act Attention should be drawn to the fact that parts of this unit by necessity will get VERY HOT and will cause burns if touched accidentally Therefore it is the responsibility of th...

Страница 3: ...6 2005 The products have been CE marked in compliance with the European Gas Directive 90 396 EEC The Parry Group have designed this range of units for use with the following gases and supply pressure...

Страница 4: ...time This appliance should be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which it is installed POSITI...

Страница 5: ...ppliance All gas appliances must be fitted by a competent person to gas safety regulations in force Before the appliance is commissioned the gas safety regulations require that all connections on the...

Страница 6: ...that the pilot flame has been established if not go back to step 3 6 If pilot flame is established keep knob depressed for 20 seconds then release 7 The pilot flame will continue to burn 8 Turn knob a...

Страница 7: ...parts in this unit Cleaning Cleaning should be carried out by simply wiping the exterior of the appliance with a clean cloth and a small amount of detergent to remove any build up of fat deposits fro...

Страница 8: ...y blocked injector Check clean injector Inadequate ventilation Check ventilation Burner faulty corroded blocked Check clean burner Replace as necessary Faulty flue system Check flue system Pilot will...

Страница 9: ...R KG HR NATURAL G20 0 384 M HR 13 550 FT HR PROPANE G31 37mb 0 174 M HR 6 159 FT HR 0 677 LB HR 0 307 KG HR BUTANE G30 29mb 0 138 M HR 4 866 FT HR 0 715 LB HR 0 324 KG HR AIR FLOW RATE FOR COMBUSTION...

Страница 10: ...ed out by a competent qualified person 1 Turn gas valve off disconnect unit 2 Place unit on side to expose wing nuts on under tray 3 Undo wing nuts 4 Lift under tray out 5 Undo the nut that attaches t...

Страница 11: ...ctor has been changed the pilot must be adjusted to suit the alternate gas To do this remove bung on bottom of pilot assembly see image 10 Using a screwdriver adjust pilot jet to obtain a pilot flame...

Страница 12: ...EF IN172 ISSUE No 1 DATE 30 10 09 Page 12 of 17 www parry co uk Model Injector Size Injector Code SGWBP Propane G31 37mbar 12 W G Burner Injector INJECT 119 SGWB Nat Gas G20 20mbar 8 W G Burner Inject...

Страница 13: ...INSTRUCTION REF IN172 ISSUE No 1 DATE 30 10 09 Page 13 of 17 www parry co uk EXPLODED VIEW PARTS LIST...

Страница 14: ...hole 1 12 Fixing Bracket 4 13 Spacer Bracket 4 14 Electrode ELECTRODE 1 15 Pilot PILOT3WAY 1 16 Thermocouple GWBTCOUPLE 1 17 Gas Knob KNOBPRO007 1 18 Gas Valve GWBAGASVALVE 1 19 Lower Plate 1 20 Inte...

Страница 15: ...arranty During the warranty period it is at Parry s discretion to repair or replace the equipment Warranty only applies if the equipment has been used in a professional manor following the manufacture...

Страница 16: ...s arranged for service call and engineer refused access or customer not there No faults with the machine Setting up of equipment eg dishwasher detergents levelling and setting up of doors on a 6 burne...

Страница 17: ...ove will be forwarded to the parties responsible for placing the call Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled Any iss...

Отзывы: