www.parry.co.uk
CLEANING AND MAINTENANCE
ENSURE THE APPLIANCE IS ISOLATED FROM THE POWER SUPPLY
BEFORE INSTALLING, CLEANING OR MAINTAINING THE APPLIANCE
Ensure that the appliance has cooled sufficiently.
Cleaning should be carried every day. Clean the external surfaces of the
appliance with a damp cloth. Avoid using abrasive materials.
CAUTION:
Never clean the appliance with water jets.
Appliance should be annually P.A.T (Portable Appliance Testing) tested for
continued electrical safety.
DE-SCALING
Your appliance should be periodically checked for scale build up. The frequency
depends upon the hardness of the water, the throughput and whether or not an
effective water softener or scale reducer is fitted.
Disconnect the appliance from water and electrical supply.
Lift off the top lid and unscrew the four screws holding down the tank cover.
Remove the two inner stainless steel trays.
Drain water from the tank.
It is important that the two sensors and their holders are free from scale.
Remove loose scale by hand and hard scale by use of suitable de-scaling
powder or liquid. Please refer to the guidelines of the de-scaling product for
correct use.
Rinse the tank thoroughly with water to ensure that all of the de-scaling product is
removed before use.
Replace inner trays and tank cover, secure with the four screws and replace the
lid.