INSTRUCTION REF: IN100             
ISSUE No.  6  
DATE  06.06.16 
Page 8 of 21  

 

www.parry.co.uk 

OPERATING INSTRUCTIONS 

 

FOR FITTING INSTRUCTIONS SEE INSTALLATION SECTION. 

 

OPERATION 
 

Upon the completion of installation, turn on the water supply and the electrical 
supply. 
 
Turn on the power switch located at the front of the appliance.  
 
The indicator lamp will cycle through a series of colours for 4 seconds whilst the 
unit does a self diagnostics check.  
 
The indicator lamp will glow yellow to show that the appliance is filling to the low 
level sensor.  
 
When the water level is reached the indicator lamp will then glow blue, to indicate 
that the heating cycle has commenced.  
 
As the temperature of water increases the indicator lamp will slowly change 
colour from blue through to red. On first installation, please wait for approximately 
25 minutes before use as this will allow the appliance to fill completely and be at 
full working temperature. 
 
Please note the appliance does not completely fill at once it is controlled 
electronically. 
 
Place cup or container under the tap and pull the lever towards you to dispense 
hot water.  
 
If the indicator light shows different colours to those described above then please 
refer to fault diagnostics on page 13 & 14 of this instruction booklet. 
 

 
 
 
 

Содержание AWB3

Страница 1: ...L DATA INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS EXPLODED VIEW PARTS LIST FAULT DIAGNOSTICS WIRING DIAGRAM WARRANTY INFORMATION DISPOSAL INFORMATION Customer Informatio...

Страница 2: ...G MUST BE FITTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT REGULATIONS The unit should be installed in compliance with the INSTALLATION INSTRUCTIONS and the NATIONAL REGULATIONS in force a...

Страница 3: ...built to comply with the following standards BS EN 60335 1 WRAS Approved GENERAL INFORMATION Installation of water boilers must comply with the requirements of the water supply water fittings regulati...

Страница 4: ...50 Hz Nominal Current 25Amps Nominal Wattage 6 kW Unit must be hard wired to suitable isolator spur Min Max water pressure 1 10 Bar Water Capacity 14 6 litres Dimensions mm 315 w X 505 d X 614 h Weigh...

Страница 5: ...lement Parry Group Ltd strongly recommends that you use a food quality water softener or scale reducer Provide a water stop cock next the appliance Water Inlet Supplied with boiler The appliance is fi...

Страница 6: ...event of component failure Parry Group Ltd strongly recommend that the overflow be plumbed to a suitable drain During operation there will be an occasional small discharge of steam and condensation f...

Страница 7: ...nect the overflow pipe to the left hand side port Fit overflow to a suitable drain Remove red cap and connect water inlet hose Connect water inlet hose to BSP water connection Under no circumstances s...

Страница 8: ...When the water level is reached the indicator lamp will then glow blue to indicate that the heating cycle has commenced As the temperature of water increases the indicator lamp will slowly change col...

Страница 9: ...ecked for scale build up The frequency depends upon the hardness of the water the throughput and whether or not an effective water softener or scale reducer is fitted Disconnect the appliance from wat...

Страница 10: ...s serviced every 12 months by a Parry authorised engineer Failure to service your product within the initial 12 month warranty period will cause the 24 month warranty to become void MAINTENANCE AND SE...

Страница 11: ...INSTRUCTION REF IN100 ISSUE No 6 DATE 06 06 16 Page 11 of 21 www parry co uk EXPLODED VIEW VIEW AWB3 ONLY ADDITIONAL PARTS FOR AWB6 ARE SHOWN ON PAGE 10...

Страница 12: ...NGLID AWB6 2 CONDENSING LID 14 3kW Element AWB3 2ELEM ELBW03000 15 Inlet Solenoid Hose AWB3 2SOLHOSE AWB3 2SOLHOSE 16 Overflow Steam Hose Assembly AWB3 2INNEROF AWB3 2INNEROF 16a Outlet Overflow Pipe...

Страница 13: ...YELLOW Filling Need to fill within 40 sec BLUE PURPLE RED Heat up cycle from power up RED Boiler has reached operating temperature GREEN Boiler needs de scaling The boiler will still continue to work...

Страница 14: ...ineer PURPLE RED FLASH The heater has failed to heat the tank in time Approx 15 minutes Call Engineer GREEN BLUE FLASH The water has failed to reach temperature in 120 minutes Call Engineer RED WHITE...

Страница 15: ...INSTRUCTION REF IN100 ISSUE No 6 DATE 06 06 16 Page 15 of 21 www parry co uk WIRING DIAGRAM...

Страница 16: ...or too low it can be adjusted manually This does not require the need for a service engineer To adjust the temperature A Remove the plastic blanking plug from the lower panel to show adjustment knob...

Страница 17: ...has not been carried out in accordance with the manufacturer s instructions See installation details Also the misuse alteration or unauthorised repairs of the equipment will invalidate the warranty D...

Страница 18: ...all warranty requests be submitted to Parry via email to warranty parry co uk It is at the discretion of PARRY whether to honour a service call which is out of the warranty period Not Covered Under Wa...

Страница 19: ...iring junction box fault wrong fuse Any damages caused by the customer Lamps glass door gaskets Perspex baskets knobs all perishable items are not covered This appliance should be routinely serviced t...

Страница 20: ...icates that this appliance may not be treated as household waste Instead it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment Disposal m...

Страница 21: ...ct the units manufacturer importer or their agent the contact details will be on the unit There will probably be a charge for this service which will depend on the physical size and location of the un...

Отзывы: