11
Installation
Please note the rear panel of the cabinetry must be removed to ensure adequate
ventilation.
The power switch or socket that connects to the appliance should not be located in
the installation housing, but rather in an adjacent cabinet or above the worktop.
The panels that are immediately adjacent to the oven must be of a material that has
heat resistant qualities. In particular, cabinets with veneer finishes must be assembled
with glues that can withstand temperatures of up to 120°C. Special attention must be
paid to the edge banding finish on the cabinetry. Special care must be taken with
vacuum applied veneers commonly referred to as “thermowrap”. If in doubt, always
refer to the technical data supplied by the kitchen cabinetry manufacturer.
In order to ensure adequate ventilation, the
back of the cabinet unit must be removed. If the
oven rests on a continuous panel there must be
an aperture of at least 560mm wide by 45mm
deep from the rear of the cabinet.