PDAP 75 A1
■
70
│
GB
│
MT
Maintenance and cleaning
WARNING! RISK OF INJURY! Disconnect the
appliance from the compressed air supply.
CAUTION!
►
Before maintenance, clean off any hazardous substances that
may (due to working processes) have accumulated on the
appliance . Avoid all skin contact with these substances . If the
skin comes into contact with hazardous dusts, this can lead
to severe dermatitis . If dust is produced or swirled up during
maintenance, it can be inhaled .
NOTE
To ensure correct functioning and long-term durability of the
compressed air polisher, pay attention to the following points:
■
Sufficient and continuously intact oil lubrication is highly import-
ant for optimum functioning .
■
Check the speed and vibration levels after each use .
■
Check the idle speed regularly and after any maintenance is
performed:
use a rev counter and perform the measurement without any
clamped tools . At a residual pressure of 6 .3 bar, the idle speed
may not be exceeded under any circumstances .
■
If the appliance is exhibiting excessive vibration levels, the cause
of the vibrations must be identified and repaired .
■
Use only the genuine replacement parts recommended by the
manufacturer, otherwise you could put users at risk . In doubt,
contact the Service Centre .
■
Check the polishing disc regularly for damage .
■
Clean the appliance with a soft, dry cloth only .
■
Never use sharp or abrasive cleaning agents under any circumstances .
Содержание PDAP 75 A1
Страница 3: ......
Страница 105: ...PDAP 75 A1 102 DE AT CH...