General Guidance 

It is important that your stove is correctly installed and operated as Hunter Stoves Group cannot accept responsibility 
for any fault arising through incorrect installation, use, maintenance or servicing. 

 

These instructions cover the basic principles to ensure satisfactory installation of the stove, although details may need 
slight modifications to suit particular local site conditions.   

 

The installation must comply with current Building Regulations, National and European Standards, Local Authority 
Byelaws and other specifications or regulations as they affect the installation of the appliance.   

 

The Building Regulations requirements may also be met by adopting the relevant recommendations in the current 
issues of British Standards BS 8303 and BS EN 15287-1. 

 

Only use approved fuels on this appliance. Information about this can be found on Page 23.  

 

This is a Domestic Appliance and must only be used in accordance with these instructions. Do not place articles that 
are affected by high temperatures on, or near, this appliance. Do not place furniture or other items within 1 metre of 
the front of this appliance. See the note on material clearances on pages 17-19. 

 

Fitting a stove in a room which also contains an extractor fan and/or cooker hood should be avoided where possible. 
If this is unavoidable, the suitability of the space for fitting this appliance must be decided at the discretion of a 
qualified installer, and a flue draught interference test must be performed. 

 

Do not obstruct the ventilation required for the safe use of this appliance. 

 

Competent Persons Scheme 

Hunter Stoves Group recommend that this stove be installed by a member of an accredited competent persons 
scheme e.g. HETAS.   

 

If the installer is not a member of a competent 

person’s scheme, it is a legal requirement, in the UK, to notify your 

Local Building Control Officer in advance of any installation work starting. 

 

Health and Safety Precautions 

Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work 
Act are met. 

 

Handling 

This appliance is very heavy.  Adequate facilities must be available for loading, unloading and site handling.  

 

Fire Cement 

Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of 
contact, wash immediately with plenty of water.  

 

Asbestos 

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation, then 
please seek specialist guidance and use appropriate protective equipment.  

 

 

PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION. KEEP THESE 

INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING. 

 

THIS APPLIANCE WILL BECOME VERY HOT WHEN USED IN ACCORDANCE WITH THESE INSTRUCTIONS, 

HUNTER STOVES RECOMMEND THAT AN APPROVED GUARD IS USED TO PROTECT THE YOUNG, ELDERLY 

OR INFIRM FROM HARM. 

 

THE INSTALLER COMMISSIONING SHEET CAN BE FOUND ON THE BACK COVER. PLEASE ENSURE THAT IT IS 

COMPLETED PRIOR TO USE. 

 

Содержание ASPECT 4/4 COMPACT

Страница 1: ...ACT ASPECT 5 5 COMPACT ASPECT 5 SLIMLINE ASPECT 6 ASPECT 7 ASPECT 8 SLIMLINE ASPECT 8 ASPECT 9 ASPECT 14 WOODBURING STOVE MODELS Instructions for Installation Operating Maintenance Servicing JINSPADA...

Страница 2: ...2 STOVE MODELS ASPECT 4 ASPECT 4 COMPACT CVSPA04WS CVSPA04WB CVSPA04CWS CVSPA04CWB ASPECT 5 ASPECT 5 COMPACT CVSPA05WS CVSPA05WB CVSPA05CWS CVSPA05CWB...

Страница 3: ...MLINE ASPECT 6 CVSPA05SWS CVSPA05SWB CVSPA06WS CVSPA06WB ASPECT 7 ASPECT 8 SLIMLINE CVSPA07WS CVSPA07WB CVSPA08SWS CVSPA08SWB ASPECT 8 ASPECT 9 CVSPA08WS CVSPA08WB CVSPA09WS CVSPA09WB ASPECT 14 CVSPA1...

Страница 4: ...OPERATING INSTRUCTIONS 20 23 MAINTENANCE SERVICING 23 25 TROUBLESHOOTING DATA PLATE 26 27 SPARES 28 34 COMMISSIONING INSTALLATION CHECK LIST 35 SERVICE RECORDS 36 FULL WARRANTY INFORMATION 37 38 Welc...

Страница 5: ...5mm 125mm 125mm 125mm VENTILATION Where leakage is greater than 5m hour m Ventilation normally required 550mm per kW output over 5kW NONE NONE NONE NONE NONE NONE Where leakage is less than or equal t...

Страница 6: ...Aspect 7 Aspect 8 Slimline Aspect 8 Aspect 9 Aspect 14 Energy Efficiency Class A A A A A Nominal Heat Output Wood 4 9kW 4 9kW 6 0kW 8 0kW 9 5kW Energy Efficiency EEI 103 105 105 97 97 Efficiency Wood...

Страница 7: ...e discretion of a qualified installer and a flue draught interference test must be performed Do not obstruct the ventilation required for the safe use of this appliance Competent Persons Scheme Hunter...

Страница 8: ...his appliance should not be operated with the door open If fume emission persists then the following immediate action should be taken Open doors and windows to ventilate the room Let the fire go out o...

Страница 9: ...s well as protect the internal components from damage during the installation process Fuel Retainer Bottom Grate Brick Side Bricks Open the door and remove the fuel retainer A Lift upwards B push inwa...

Страница 10: ...op one edge downward into the bottom of the stove and pull outwards B Place the flue collar gaskets on the outlet to be used Push the upper brick upwards A Then pull the bottom edge of the rear brick...

Страница 11: ...by contacting your Local Authority To remove the secondary air stop remove the two screws and then take off the plate as per the diagram below Re Assembling The Stove Refit all the internal parts by f...

Страница 12: ...12 Appliance Dimensions Aspect Dimensions Aspect 4 Compact Aspect 4 BOTH COMPACT STANDARD Dimensions Aspect 5 Compact Aspect 5 BOTH COMPACT STANDARD Dimensions Aspect 5 Slimline...

Страница 13: ...13 Dimensions Aspect 6 Dimensions Aspect 7 Dimensions Aspect 8 Slimline...

Страница 14: ...14 Dimensions Aspect 8 Dimensions Aspect 9 Dimensions Aspect 14...

Страница 15: ...e chimney flue system for cleaning and the removal of debris If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a...

Страница 16: ...f the Health Safety code of practice and any other legislation that may have been introduced since the publication of these instructions Competent Persons Scheme Members of the following schemes may s...

Страница 17: ...The optional rear and upper heat shields must be fitted to achieve these distances The standard clearance without these would revert to 900mm Combustible material refers to any material that will degr...

Страница 18: ...left hand edge clear of the stove body and remove To fit the heat shield for the Slimline s and 8 position the left hand edge and then flex the heat shield until the right hand edge clears the stove b...

Страница 19: ...ith all of the windows and doors to the room where the appliance is fitted closed If there are any adjoining room s that have an Extractor Fan fitted open the adjoining door to ensure that the chimney...

Страница 20: ...ction 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers Further information on the requirements of the Clean A...

Страница 21: ...a traditional stove if used correctly with the obvious notable feature of CLEAN GLASS It is essential that the stove has an adequate air supply for combustion and ventilation A When the air control ro...

Страница 22: ...fire pull the air control rod until it is fully open B then push it in halfway for normal burning C Warning The stove will remain hot for a considerable time after the fire has been extinguished Note...

Страница 23: ...as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove i e get the chimney swept before the start of the heating seaso...

Страница 24: ...gs are continually jammed against them or if they are frequently struck with a poker Check periodically for seriously cracked bricks which can be replaced with new available from your dealer or our sp...

Страница 25: ...ny delay in receiving replacement components should you need them If you feel unable to undertake this task Hunter Stoves recommend that you contact the installation engineer for advice Remove all the...

Страница 26: ...e smoke spillage into room when appliance door is opened Low flue draught Speak to your installer Incorrect additional ventilation air in to the building Speak to your installer Continuous smoke spill...

Страница 27: ...e content over 20 Use dry seasoned wood less than 20 moisture content Glass blackening Using poor quality wood Use dry seasoned wood less than 20 moisture content Low flue draught Speak to your instal...

Страница 28: ...mper taller flue collar needed CH05010 HHR99992 MULTIFUEL CONVERSION KITS Aspect 4 JPA04 Aspect 4 Compact JPA04C Aspect 5 JPA05 Aspect 5 Compact JPA05C Aspect 5 Slimline JPA05S Aspect 6 JPA06 Aspect 7...

Страница 29: ...4 COMPACT ASPECT 4 DOOR FRONT VIEW ASPECT 4 COMPACT ASPECT 4 DOOR REAR VIEW ASPECT 5 COMPACT ASPECT 5 DOOR FRONT VIEW ASPECT 5 COMPACT ASPECT 5 DOOR REAR VIEW ASPECT 5 SLIMLINE 6 DOOR FRONT VIEW ASPEC...

Страница 30: ...30 ASPECT 7 DOOR FRONT VIEW ASPECT 7 DOOR REAR VIEW ASPECT 8 8 SLIMLINE 9 AND 14 DOOR FRONT VIEW ASPECT 8 8 SLIMLINE 9 AND 14 DOOR REAR VIEW BODY ASSEMBLY SPARES ASPECT COMPACT 4 AND 4...

Страница 31: ...31 BODY ASSEMBLY SPARES ASPECT COMPACT 5 AND 5 BODY ASSEMBLY SPARES ASPECT 5 SLIMLINE...

Страница 32: ...32 BODY ASSEMBLY SPARES ASPECT 6 BODY ASSEMBLY SPARES ASPECT 7...

Страница 33: ...33 BODY ASSEMBLY SPARES ASPECT 8 BODY ASSEMBLY SPARES ASPECT 8 SLIMLINE...

Страница 34: ...34 BODY ASSEMBLY SPARES ASPECT 9 BODY ASSEMBLY SPARES ASPECT 14...

Страница 35: ...escription Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundness test Has th...

Страница 36: ...nature 9th Service Date of Service Date of next Service Servicing Company Engineer Signature 2nd Service Date of Service Date of next Service Servicing Company Engineer Signature 4th Service Date of S...

Страница 37: ...12 months of the installation date for the second year of the standard warranty to be valid and within every 12 month anniversary thereafter to maintain the validity and coverage of any extended warra...

Страница 38: ...ssociated non Hunter Stoves Group products is not covered under the warranty 6 Consequential loss relating to decorations soft furnishings or other household assets is not covered under the warranty 7...

Отзывы: