background image

37 

 

 

 

Hunter Stoves Group Ltd Extended 5 and 10 Year Warranty 

 

 

 

2 Year Standard Warranty 

 

Any appliance bought through the showroom of an authorised Hunter Stoves Group dealership will automatically be 
covered by our standard 2-year conditional guarantee. 

 

However, this standard 2-year warranty can be extended to a 

5 year

 or 

10-year 

conditional warranty dependent on 

the model type (5 years- Boiler model and Gas models, 10 years- Room heater). 

 

To qualify for this extended warranty option, you need to: 

 

1.  Register your purchase online at https://www.hunterstoves.co.uk/ProductRegistration 
2.  Retain your proof of purchase. 

 

Warranty Conditions 

 

For the Standard 2 year or extended 5/10-year warranty to be valid and to remain in force throughout the warranty 
period the following must have been carried out: 

 

1.  The appliance must have been installed by an appropriately qualified engineer (from the Competent Person 

Scheme/Gas Safe) in accordance with the 

manufacturer’s instructions and in compliance of any relevant 

national or local building regulations. Please visit the following links for details on the Competent Person 
Scheme

https://www.gov.uk/guidance/competent-person-scheme-current-schemes-and-how-schemes-are-

authorised

 and Gas Safe register: 

https://www.gassaferegister.co.uk/

 

 

2.  The appliance will need to be registered within two months of purchase and the commissioning and 

installation documentation completed (these need to be kept by the end user).  

 

3.  The appliance must be serviced within 12 months of the installation date for the second year of the standard 

warranty to be valid, and within every 12-month anniversary thereafter to maintain the validity and coverage 
of any extended warranty. For this purpose, the installation and user instructions, supplied with the appliance, 
makes a provision for receipts and annual services to be recorded. This is needed in the event of a claim 
during the warranty period. 

 

4.  Only genuine Hunter Stoves spare parts or consumables can be used in the servicing and maintenance of the 

appliance during any standard or extended warranty period. These can be sourced from your authorised 
supplier directly or through our website spares portal. www.hunterstoves.co.uk/spares. 

 

5.  Any problems or issues giving rise to any claim under the standard or extended warranty must be submitted to 

the authorised Hunter Stoves Group retailer from whom you originally purchased the appliance. Hunter 
Stoves Group will then offer appropriate support and help through your original authorised supplier to solve 
any issues. 

 

6.  The standard or extended warranty option is not transferable. It is solely for the benefit of the original 

purchaser of the appliance. For this purpose, please retain the proof of purchase.  

 

Warranty Exclusions 

 
No warranty period is extended to naturally-wearing replaceable consumables and spare parts within the appliance. 
Such parts include, but are not limited to: 
 

For Solid Fuel Stoves: 

Glass and rope/ceramic seals  
Fire bricks 
Baffles/Throat plates 
Log retainers, grate supports & catch bars 
Grate parts  
Ash-pans 
Clip-in Boilers 
 

For Gas Stoves: 

Gas pilot assemblies  
Thermocouples and Oxy pilots 
Ceramic log & coal 'fuel -effects' 
Batteries 
 

Содержание ASPECT 4/4 COMPACT

Страница 1: ...ACT ASPECT 5 5 COMPACT ASPECT 5 SLIMLINE ASPECT 6 ASPECT 7 ASPECT 8 SLIMLINE ASPECT 8 ASPECT 9 ASPECT 14 WOODBURING STOVE MODELS Instructions for Installation Operating Maintenance Servicing JINSPADA...

Страница 2: ...2 STOVE MODELS ASPECT 4 ASPECT 4 COMPACT CVSPA04WS CVSPA04WB CVSPA04CWS CVSPA04CWB ASPECT 5 ASPECT 5 COMPACT CVSPA05WS CVSPA05WB CVSPA05CWS CVSPA05CWB...

Страница 3: ...MLINE ASPECT 6 CVSPA05SWS CVSPA05SWB CVSPA06WS CVSPA06WB ASPECT 7 ASPECT 8 SLIMLINE CVSPA07WS CVSPA07WB CVSPA08SWS CVSPA08SWB ASPECT 8 ASPECT 9 CVSPA08WS CVSPA08WB CVSPA09WS CVSPA09WB ASPECT 14 CVSPA1...

Страница 4: ...OPERATING INSTRUCTIONS 20 23 MAINTENANCE SERVICING 23 25 TROUBLESHOOTING DATA PLATE 26 27 SPARES 28 34 COMMISSIONING INSTALLATION CHECK LIST 35 SERVICE RECORDS 36 FULL WARRANTY INFORMATION 37 38 Welc...

Страница 5: ...5mm 125mm 125mm 125mm VENTILATION Where leakage is greater than 5m hour m Ventilation normally required 550mm per kW output over 5kW NONE NONE NONE NONE NONE NONE Where leakage is less than or equal t...

Страница 6: ...Aspect 7 Aspect 8 Slimline Aspect 8 Aspect 9 Aspect 14 Energy Efficiency Class A A A A A Nominal Heat Output Wood 4 9kW 4 9kW 6 0kW 8 0kW 9 5kW Energy Efficiency EEI 103 105 105 97 97 Efficiency Wood...

Страница 7: ...e discretion of a qualified installer and a flue draught interference test must be performed Do not obstruct the ventilation required for the safe use of this appliance Competent Persons Scheme Hunter...

Страница 8: ...his appliance should not be operated with the door open If fume emission persists then the following immediate action should be taken Open doors and windows to ventilate the room Let the fire go out o...

Страница 9: ...s well as protect the internal components from damage during the installation process Fuel Retainer Bottom Grate Brick Side Bricks Open the door and remove the fuel retainer A Lift upwards B push inwa...

Страница 10: ...op one edge downward into the bottom of the stove and pull outwards B Place the flue collar gaskets on the outlet to be used Push the upper brick upwards A Then pull the bottom edge of the rear brick...

Страница 11: ...by contacting your Local Authority To remove the secondary air stop remove the two screws and then take off the plate as per the diagram below Re Assembling The Stove Refit all the internal parts by f...

Страница 12: ...12 Appliance Dimensions Aspect Dimensions Aspect 4 Compact Aspect 4 BOTH COMPACT STANDARD Dimensions Aspect 5 Compact Aspect 5 BOTH COMPACT STANDARD Dimensions Aspect 5 Slimline...

Страница 13: ...13 Dimensions Aspect 6 Dimensions Aspect 7 Dimensions Aspect 8 Slimline...

Страница 14: ...14 Dimensions Aspect 8 Dimensions Aspect 9 Dimensions Aspect 14...

Страница 15: ...e chimney flue system for cleaning and the removal of debris If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a...

Страница 16: ...f the Health Safety code of practice and any other legislation that may have been introduced since the publication of these instructions Competent Persons Scheme Members of the following schemes may s...

Страница 17: ...The optional rear and upper heat shields must be fitted to achieve these distances The standard clearance without these would revert to 900mm Combustible material refers to any material that will degr...

Страница 18: ...left hand edge clear of the stove body and remove To fit the heat shield for the Slimline s and 8 position the left hand edge and then flex the heat shield until the right hand edge clears the stove b...

Страница 19: ...ith all of the windows and doors to the room where the appliance is fitted closed If there are any adjoining room s that have an Extractor Fan fitted open the adjoining door to ensure that the chimney...

Страница 20: ...ction 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers Further information on the requirements of the Clean A...

Страница 21: ...a traditional stove if used correctly with the obvious notable feature of CLEAN GLASS It is essential that the stove has an adequate air supply for combustion and ventilation A When the air control ro...

Страница 22: ...fire pull the air control rod until it is fully open B then push it in halfway for normal burning C Warning The stove will remain hot for a considerable time after the fire has been extinguished Note...

Страница 23: ...as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove i e get the chimney swept before the start of the heating seaso...

Страница 24: ...gs are continually jammed against them or if they are frequently struck with a poker Check periodically for seriously cracked bricks which can be replaced with new available from your dealer or our sp...

Страница 25: ...ny delay in receiving replacement components should you need them If you feel unable to undertake this task Hunter Stoves recommend that you contact the installation engineer for advice Remove all the...

Страница 26: ...e smoke spillage into room when appliance door is opened Low flue draught Speak to your installer Incorrect additional ventilation air in to the building Speak to your installer Continuous smoke spill...

Страница 27: ...e content over 20 Use dry seasoned wood less than 20 moisture content Glass blackening Using poor quality wood Use dry seasoned wood less than 20 moisture content Low flue draught Speak to your instal...

Страница 28: ...mper taller flue collar needed CH05010 HHR99992 MULTIFUEL CONVERSION KITS Aspect 4 JPA04 Aspect 4 Compact JPA04C Aspect 5 JPA05 Aspect 5 Compact JPA05C Aspect 5 Slimline JPA05S Aspect 6 JPA06 Aspect 7...

Страница 29: ...4 COMPACT ASPECT 4 DOOR FRONT VIEW ASPECT 4 COMPACT ASPECT 4 DOOR REAR VIEW ASPECT 5 COMPACT ASPECT 5 DOOR FRONT VIEW ASPECT 5 COMPACT ASPECT 5 DOOR REAR VIEW ASPECT 5 SLIMLINE 6 DOOR FRONT VIEW ASPEC...

Страница 30: ...30 ASPECT 7 DOOR FRONT VIEW ASPECT 7 DOOR REAR VIEW ASPECT 8 8 SLIMLINE 9 AND 14 DOOR FRONT VIEW ASPECT 8 8 SLIMLINE 9 AND 14 DOOR REAR VIEW BODY ASSEMBLY SPARES ASPECT COMPACT 4 AND 4...

Страница 31: ...31 BODY ASSEMBLY SPARES ASPECT COMPACT 5 AND 5 BODY ASSEMBLY SPARES ASPECT 5 SLIMLINE...

Страница 32: ...32 BODY ASSEMBLY SPARES ASPECT 6 BODY ASSEMBLY SPARES ASPECT 7...

Страница 33: ...33 BODY ASSEMBLY SPARES ASPECT 8 BODY ASSEMBLY SPARES ASPECT 8 SLIMLINE...

Страница 34: ...34 BODY ASSEMBLY SPARES ASPECT 9 BODY ASSEMBLY SPARES ASPECT 14...

Страница 35: ...escription Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundness test Has th...

Страница 36: ...nature 9th Service Date of Service Date of next Service Servicing Company Engineer Signature 2nd Service Date of Service Date of next Service Servicing Company Engineer Signature 4th Service Date of S...

Страница 37: ...12 months of the installation date for the second year of the standard warranty to be valid and within every 12 month anniversary thereafter to maintain the validity and coverage of any extended warra...

Страница 38: ...ssociated non Hunter Stoves Group products is not covered under the warranty 6 Consequential loss relating to decorations soft furnishings or other household assets is not covered under the warranty 7...

Отзывы: