CONNECTING TO THE MAINS TERMINAL
We recommend you use a new length of 6mm
2
twin core and earthed cable to ensure your safety.
Make connection by proceeding as follows:-
Preform wires to the appropriate shape to suit fitting into the mains terminal block.
Strip inner insulation on wires using wire strippers.
Twist the bared wires using pliers.
Cut bared wires 10mm away from the end of the inner insulation. Where uninsulated Earth wires are
used ensure they are suitably sheathed to leave 10mm bare wire to fit into the terminal.
Clamp bare wires into the relevant terminal (fig 2) and check they are held by tugging each one in
turn.
Clamp the mains cable securely ensuring 5mm of the outer insulation is inside the terminal block and
that the wires are not taught but not so slack as to cause any fouling.
Connect the remaining end of the mains cable to the cooker point / junction box
Place fuse / miniature circuit breaker in circuit and switch on at mains.
NOTE: HOUSE CIRCUIT
Earth leakage / continuity tests must be carried out before the cooker is connected to the mains supply
and re-checked after fitting.
fig 2
INSTALLATION INSTRUCTIONS