![Parker SPD 16 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/parker/spd-16/spd-16_user-manual_756088087.webp)
Parker Hannifin S.p.A. - Divisione S.B.C. “SPD” User’s Manual
86
Multiple synchronism message from Master to SPD
MultiSynchronism message
Data length
1 bytes
Field Name
Data
Contents
Command 0
Command 1
Command 2
Command 3
Identifier
ID2 ID1 ID0 -
-
-
-
- ID10 ID9 ID8 ID7 ID6 ID5 ID4 ID3
0 0 0 X X X X X 0 0 0 0 0 1 0 0
Each drive receives and executes the speed reference and saves the actual motor position; if
b150.2=1 the drive answers with a “
cyclic reply
”.
This message is for several drives. The following table shows to which drive the “Command”
(Pr102 – first 8 bit) is sent to.
Drive Command0 Command
1
Command 2
Command 3
Drive1 YES
Drive2 YES
Drive3
YES
Drive4
YES
Drive5
YES
Drive6
YES
Drive7
YES
Drive8
YES
Drive9 YES
Drive10 YES
Drive11
YES
Drive12
YES
Drive13
YES
Drive14
YES
Drive15
YES
Each command is made up of 8 bit (Pr102) and it is sent to several drives. Each command
value is set by the user through the pico-PLC of each drive.