25
HP Pump Delay Time
This delay timer controls the startup delay applied to the high-pressure pump during system
activation. The default delay time is 10 seconds, but if your application has the booster pump
located some distance away from the main unit, a longer delay may be required to allow the
feed water to reach the high-pressure pump. The time value delay range is from 5 seconds to 99
seconds.
4.
Press Tank Level Switch to change default setting tank level switch
Tank Level Switch Delay Time
This delay timer controls the delay period applied to the state change of the production tank level
switches. As the tank begins to fill with fresh water and with movement of the vessel, the water
level within the tank will oscillate. This oscillation will cause constant activation and de-activation
of the product tank level switches when the tank level is near their detection point, this
programmable delay period is designed to accommodate for these oscillations, so false triggering
of these level switches is avoided. The time value delay range is from 5 minutes to 99 minutes.
5.
Press Water Production to change default setting to the desired amount before system
shutdown. A value of zero ‘0’ will de-activate this feature.
Press here
Auto Production
Setting Area
Содержание Sea Recovery Aquamatic
Страница 19: ...19 ...