XPR2/XPC2 PowerStation Series Hardware User Guide
Page 39 of 47
Closing the PowerStation
1. Ensure that the CompactFlash card is not inserted in the motherboard and carefully replace the
backshell on the PowerStation.
2. Remount the PowerStation in the enclosure; refer to
Installing the PowerStation
.
3. Reconnect the following cables:
•
Power Input cable
•
Ground
cable
•
any
communication
cables
•
any keyboard and mouse cables
4. Turn on the PowerStation
Replacing the Fuse
The XPR2/XPC2 PowerStation has a protective fuse that you can replace by opening up the back cover. An
ohm meter is required to see whether the fuse is still operational. The required replacement fuse is listed below.
•
Use a Littelfuse Nano SMF Slow Blow Type fuse. The part number is R452 002.
Caution
—
Using a fuse of a different rating can cause damage to the unit
or fire to occur.
To replace the fuse, complete the following steps:
1. Remove the PowerStation from its enclosure discussed in
Removing the PowerStation from the
Enclosure
.
2. Remove the back enclosure.
3. Locate the fuse on the board according to the picture below.
4. Using an ohmmeter, check continuity to see if the fuse is blown.
5. If necessary, insert a new fuse into the fuse holder and reassemble the unit.