Parker PowerStation XPR2 Series Скачать руководство пользователя страница 1

XPR2/XPC2 PowerStation Series 
Hardware User Guide

 

Parker Hannifin 

Electromechanical Automation - NA 

5500 Business Park Drive 

Rohnert Park, CA 94928

 

July 2011

 

Part #: 88-026522-01A 

Содержание PowerStation XPR2 Series

Страница 1: ...XPR2 XPC2 PowerStation Series Hardware User Guide Parker Hannifin Electromechanical Automation NA 5500 Business Park Drive Rohnert Park CA 94928 July 2011 Part 88 026522 01A...

Страница 2: ...Display XPR200 XPC200 PowerStation Mounting Procedures 12 6 XPR2 XPC2 PowerStation Mounting Procedures 13 8 XPR2 XPC2 PowerStation Mounting Procedures 14 10 XPR2 XPC2 PowerStation Mounting Procedures...

Страница 3: ...an Enclosure 37 Closing the PowerStation 39 Replacing the Fuse 39 Resolving Problems 40 The PowerStation Documentation and Utilities CD 40 Appendix A PowerStation Specifications 41 Physical Specifica...

Страница 4: ...from the factory Exceptions appear below PowerStation CCFL backlight bulbs have a 90 day warranty For all displays image retention burn in is not covered by warranty Software revisions that occur wit...

Страница 5: ...peration This manual is divided into the following chapters Introduction Presents an overview of this manual the other documentation and software provided with the XPR2 XPC2 PowerStation and the steps...

Страница 6: ...XGA Each PowerStation is also shipped with a utilities CD containing this manual drawings and CAD models of each size unit applicable drivers and backup copies of available software Downloading Appli...

Страница 7: ...exposure to adverse conditions such as dust oil moisture condensation and corrosive vapors The XPR2 XPC2 PowerStation s touchscreen faceplate assembly is designed to meet the NEMA Type 4X Indoor Use...

Страница 8: ...ted to exceed 50o C An example of this type of installation would be a PowerStation mounted in a small sealed industrial enclosure The most commonly overlooked aspect of this type of installation is t...

Страница 9: ...d back of the PowerStation Make sure that the surface of the enclosure on which the PowerStation is mounted is flat and free of raised or depressed areas Refer to the XPR2 XPC2 Utilities Drivers Docum...

Страница 10: ...rning Explosion Hazard Substitution of components may impair suitability for Class I Division 2 Do not disconnect equipment unless power has been switched off or the area is known to be non hazardous...

Страница 11: ...existing cutouts created for older XPR XPC PA and PA2 PowerStations and they can use the existing DC power source Creating a Cutout Be sure to follow the cutout diagrams in the dimensional drawings pr...

Страница 12: ...depending on the display size 6 8 10 or 15 To mount the PowerStation properly refer to the instructions below that correspond with the proper display size Non Display XPR200 XPC200 PowerStation Mount...

Страница 13: ...bottom 5 Insert the clamp into the wide end of the slot and slide it to the thin end 6 Tighten each of the mounting screws against the front of the enclosure 7 Torque the screws until the gasket is c...

Страница 14: ...bottom 5 Insert the clamp into the wide end of the slot and slide it to the thin end 6 Tighten each of the mounting screws against the front of the enclosure 7 Torque the screws until the gasket is c...

Страница 15: ...and 1 on each side 5 Insert the clamp into the wide end of the slot and slide it to the thin end 6 Tighten each of the mounting screws against the front of the enclosure 7 Torque the screws until the...

Страница 16: ...thin end as shown in the following figure 5 Tighten each of the mounting screws against the front of the enclosure 6 Torque the screws to 7 in lbs in a crosswise sequence to ensure a good seal and pre...

Страница 17: ...XPR2 XPC2 PowerStation Series Hardware User Guide Page 17 of 47 The following chart summarizes the various clamp quantities styles and tightness torques require for mounting each unit size...

Страница 18: ...werStation using AC power Caution Do not apply AC line input power directly to the unit or damage may occur Preparing a Location for the AC Power Supply Be sure to select a location that provides prot...

Страница 19: ...ith external devices at baud rates of up to 115K baud The COM1 port supports RS 232 while COM2 supports configurable RS 232 RS 422 and RS 485 communication standards The communication standard you sel...

Страница 20: ...nouts and signal information for COM2 depending on the communication configuration selected Pin RS 232 Communication RS 422 Communication RS 485 Communication 1 N C TXD transmitted data TXD transmitte...

Страница 21: ...h settings complete the following steps 1 Choose the appropriate DIP switch settings from the diagram displayed on the side of the XPR2 XPC2 PowerStation and the chart above 2 Using a pointed instrume...

Страница 22: ...modem cable refer to the following diagram Keyboard and Mouse The XPR2 XPC2 PowerStation allows you to use a USB keyboard and USB mouse in addition to the touchscreen Ethernet Port The XPR2 XPC2 Power...

Страница 23: ...are now ready for the user to download a custom Xpress application or project Please refer to the Interact Xpress User Guide that shipped with the Xpress Manager for information regarding The Xpress...

Страница 24: ...n CD Part Number KA 026518 xx supplied with unit Complete the following steps 1 Insert the XPR2 CompactFlash card into the CompactFlash card reader writer 2 Insert the XPR2 XPC2 Utilities Drivers Docu...

Страница 25: ...t Number KA 026518 xx supplied with unit Complete the following steps 1 Insert the XPC2 CompactFlash card into the CompactFlash card reader writer 2 Insert the Interact XPR2 XPC2 Utilities Drivers Doc...

Страница 26: ...ard Windows 7 and future operating systems to PowerStation embedded flash storage The following items are required to recover the Windows XP operating system A PC or laptop with a USB port and an acti...

Страница 27: ...ent while Acronis installs and the screen flashes a couple times while the software loads Recovering the operating system image to the target Compact Flash card will require the following steps a Once...

Страница 28: ...SB drive in Step 2 above Note that this image file will be located on the Removable Drive After selecting the file click the OK button d Now carefully select the 91 xxxxx xx RevX tib file image to be...

Страница 29: ...eries Hardware User Guide Page 29 of 47 f Select the Restoration Method Restore whole disks and partitions and then click the Next button g Now select the items to be restored be sure to select all it...

Страница 30: ...30 of 47 h Select the target drive to be restored to and then click Next i If the target drive is not blank and has any prior data on it then the following message will appear Click OK j On the Option...

Страница 31: ...error or warning messages that may appear Note During the reboot and at the moment of the reset beep remove the USB drive from the system to prevent the Acronis Recovery software from executing again...

Страница 32: ...Driver bat XPC210 640 x 480 Install Display Driver VGA 6 8 10 inch Driver bat XPC215 1024 x768 Install Display Driver XGA 15 inch Driver bat To install the video driver a Using the Windows File Explo...

Страница 33: ...isplayed press a corresponding letter key or use the arrow keys to navigate through the menu The following options are available Motherboard Device Configuration Allows configuration of serial port IR...

Страница 34: ...can resist with no visible effect Do not use any harsh material or powder such as steel wool or abrasive cleansers to clean the screen surface The surface is sensitive to scraping sharp blows or punct...

Страница 35: ...n release The screen guides you through the Touch Hold Release process 5 Repeat the process three more times in the other three corners of the screen A test screen appears 6 Move your finger across th...

Страница 36: ...sh socket as shown in the following figure 3 Push the ejector button two times once to extend the button then again to pop out the CompactFlash card 4 Remove the CompactFlash card 5 Carefully insert t...

Страница 37: ...grounding methods Wear a grounding wrist strap for continuous protection Be particularly careful not to touch the components on the printed circuit boards Keep any PowerStation component in its anti s...

Страница 38: ...2 Press in the eject button to return it to its retracted position 3 Remove the backshell screws on the XPR2 XPC2 PowerStation similar to the figure shown below 4 Carefully lift the backshell straight...

Страница 39: ...hat you can replace by opening up the back cover An ohm meter is required to see whether the fuse is still operational The required replacement fuse is listed below Use a Littelfuse Nano SMF Slow Blow...

Страница 40: ...roblem persists look through the other problems listed in this section to determine if additional symptoms exist that might require action If you cannot solve the problem or if you encounter a problem...

Страница 41: ...Cache Memory Up to 1 GB DDR SDRAM Maximum 400 MHz PC 3200 200 pin SODIMM Socket BIOS Insyde XpressROM Storage 256MB 8G CompactFlash card Supports Type 1 and 2 CompactFlash cards I O Ports Two 9 pin s...

Страница 42: ...Resolution QVGA 320 x 240 VGA 640 x 480 Brightness 470 NITS 350 NITS Bulb Life CCFL 75 000 hours 75 000 hours Viewing Angle Left Right Up Down 70o 70o 70o 50o 80o 80o 80o 70o XPR2 XPC208T 8 Display S...

Страница 43: ...4 Resolution VGA 640 x 480 Brightness 200 NITS Bulb Life 50 000 hours Viewing Angle Left Right Up Down 70o 70o 50o 60o XPR2 XPC215T 15 Display Specifications Property XPR2 XPC215T Description Type Ac...

Страница 44: ...ated ambient temperature you must cool the enclosure The PowerStation conforms to the environmental specifications listed in the following table Environmental Specifications Table Category Specificati...

Страница 45: ...generating electrical noise Refer to the Electrical Grounding Guidelines section for further information The XPR2 XPC2 PowerStation s electrical specifications appear in the following table Electrica...

Страница 46: ...mits EN61000 3 2 2006 Fluctuations and Flicker EN61000 3 3 1995 including A1 2001 A2 2005 Electrostatic Discharge EN61000 4 2 1995 including A1 1998 A2 2001 Radiated Electromagnetic Field Immunity EN6...

Страница 47: ...Hexane Potassium Hydroxide Kerosene Butyl Cellosolve Ammonia Water 10 Gas oil Cyclohexanone Sodium Chloride 26 Silicone oil Trichloroethylene Zinc Chloride 81 Engine oil Ethanol Cottonseed Oil Cleanse...

Отзывы: