PHastkrimp Crimper Electrical Requirements, 1 Phase
The power supply should be brought to a separate branch circuit, single-grounded receptacle. The PHastkrimp
unit has been shipped with a 6 ft. long cord without a plug. Machine is shipped without a plug so local
requirements may be satisfied.
Model
89C-062
Phase
1 phase
Voltage
230
Cycle
60 Hz
Full Load Amperes
14 amps
Circuit Fuse
20 amps
Wire size for receptacle must conform to the requirements of the National Electrical Code or the prevailing local
code. The outlet box should be located within the range of the provided cord. We strongly recommend against
the use of an extension cord. The installer must perform a ground continuity check on the power outlet box
to ensure it is properly grounded.
Electrical Requirements
IMPORTANT SAFETY NOTICE
THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS POSSESSING
ADEQUATE BACKGROUNDS OF ELECTRICAL, ELECTRONIC AND MECHANICAL
EXPERIENCE. ANY ATTEMPT TO REPAIR THIS MACHINE MAY RESULT
IN PERSONAL INJURY AND PROPERTY DAMAGE.
THE MANUFACTURER OR SELLER CANNOT BE RESPONSIBLE
FOR THE INTERPRETATION OF THIS INFORMATION, NOR CAN IT ASSUME ANY
LIABILITY IN CONNECTION WITH ITS USE.
DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT — RECONNECT ALL GROUNDING DEVICES