Parker Hannifin Corporation
Hose Products Division
Wickliffe, OH
16
Crimping Machine
PHastkrimp
Bulletin 4480-T15-US
Power unit does not
Blown fuse(s)
Replace with time-delay fuse(s) or circuit
operate
breaker(s) and check for the cause of the
overload.
Low voltage at motor
Call a qualified electrician.
On-off switch faulty
Disconnect power. Replace off-on switch.
Motor or pump assembly
Return to factory for service.
faulty
Power unit stalls before
Low voltage at motor
Call a qualified electrician.
pusher bottoms out
Lack of lubrication between
Lubricate die cavity with Citgo MP Lithoplex
dies and die cavity
lithium grease or equivalent.
Wrong fitting, hose or die
Use correct combination. See Catalog No. 4400.
ring combination
Motor vibrates or
High voltage
Call a qualified electrician.
is excessively noisy
Motor fan loose, damaged,
With power disconnected, remove motor fan
or out of balance
guard. Tighten fan screw(s), or repair fan or fan
guard by straightening. If problem continues,
return to factory for service.
Power unit runs but
Low oil supply
Refill oil reservoir with high grade AW46
cylinder does not move
hydraulic oil. Tank capacity is 5 gallons.
up or down when buttons
are pushed.
Valve or pump faulty
Contact Technical Service Department for trouble
shooting or analysis.
Incorrect motor rotation
See page 6 (Electrical Requirements) to verify
counter-clockwise motor rotation.
If you have a problem with your PHastkrimp machine:
• First check that the proper tooling, hose and fitting combinations are being used as identified in the Parker
Catalog 4400.
• Then check the following recommendations. If after the following suggested remedy, the problem persists,
call our Technical Service Department at (440) 943-5700.
Symptoms
Possible Causes
What To Do
Trouble Shooting Guide
www.comoso.com