background image

Parker Worldwide

© 2020 Parker Hannifin Corporation. All rights reserved

BULLETIN 5909 01/21

Parker Hannifin Manufacturing Ltd

Instrumentation Products 
Division Europe,

Riverside Road,
Pottington Business Park,
Barnstaple, Devon, EX31 1NP
United Kingdom
Tel.: +44 (0) 1271 313131
Fax: +44 (0) 1271 373636
www.parker.com/ipd

Parker Hannifin Corporation

Instrumentation Products Division

16101 Vallen Drive
Houston, TX 77041
Tel: + 1 (713) 466-0056
Fax: + 1 (713) 744-9892
www.parker.com/ipd

AE – UAE,

 Dubai

Tel: +971 4 8875600

[email protected]

AR – Argentina,

 Buenos Aires

Tel: +54 3327 44 4129

AT – Austria,

 Wiener Neustadt

Tel: +43 (0)2622 23501-0

[email protected]

AT – Eastern Europe,

 

Wiener Neustadt

Tel: +43 (0)2622 23501 970

[email protected]

AU – Australia,

 Castle Hill

Tel: +61 (0)2-9634 7777

AZ – Azerbaijan,

 Baku

Tel: +994 50 2233 458

[email protected]

BE/LX – Belgium,

 Nivelles

Tel: +32 (0)67 280 900

[email protected]

BR – Brazil,

 Cachoeirinha RS

Tel: +55 51 3470 9144

BY – Belarus,

 Minsk

Tel: +375 17 209 9399

[email protected]

CA – Canada,

 Grimsby, Ontario 

Tel +1 905-945-2274

[email protected]

CH – Switzerland,

 Etoy

Tel: +41 (0) 21 821 02 30

[email protected]

CN – China,

 Shanghai

Tel: +86 21 5031 2525

CZ – Czech Republic,

 Klecany

Tel: +420 284 083 111

[email protected]

DE – Germany,

 Kaarst

Tel: +49 (0)2131 4016 0

[email protected]

DK – Denmark, 

Ballerup

Tel: +45 43 56 04 00

[email protected]

ES – Spain,

 Madrid

Tel: +34 902 33 00 01

[email protected]

FI – Finland,

 Vantaa

Tel: +358 (0)20 753 2500

[email protected]

FR – France,

 Contamine s/Arve

Tel: +33 (0)4 50 25 80 25

[email protected]

GR – Greece,

 Athens

Tel: +30 210 933 6450

[email protected]

HK – Hong Kong

Tel: +852 2428 8008

HU – Hungary,

 Budapest

Tel: +36 1 220 4155

[email protected]

IE – Ireland,

 Dublin

Tel: +353 (0)1 466 6370

[email protected]

IN – India,

 Mumbai

Tel: +91 22 6513 7081-85

IT – Italy,

 Corsico (Ml)

Tel: +39 02 45 19 21

[email protected]

JP – Japan,

 Fujisawa

Tel: +(81) 4 6635 3050

KR – South Korea,

 Seoul

Tel: +82 2 559 0400

KZ – Kazakhstan,

 Almaty

Tel: +7 7272 505 800

[email protected]

LV – Latvia,

 Riga

Tel: +371 6 745 2601

[email protected]

MX – Mexico,

 Apodaca

Tel: +52 81 8156 6000

MY – Malaysia,

 Shah Alam

Tel: +603-78490800

NL – The Netherlands,

Oldenzaal

Tel: +31 (0)541 585 000

[email protected]

NO – Norway,

 Stavanger

Tel: +47 (0)51 826 300

[email protected]

NZ – New Zealand,

 Mt Wellington

Tel: +64 9 574 1744

PL – Poland,

 Warsaw

Tel: +48 (0)22 573 24 00

[email protected]

PT – Portugal,

 Leca da Palmeira

Tel: +351 22 999 7360

[email protected]

RO – Romania,

 Bucharest

Tel: +40 21 252 1382

[email protected]

RU – Russia,

 Moscow

Tel: +7 495 645-2156

[email protected]

SE – Sweden,

 Spånga

Tel: +46 (0)8 59 79 50 00

[email protected]

SG – Singapore,

Tel: +65 6887 6300

SK – Slovakia,

 Banská Bystrica

Tel: +421 484 162 252

[email protected]

SL – Slovenia,

 Novo Mesto

Tel: +386 7 337 6650

[email protected]

TH – Thailand, 

Bangkok

Tel: +662 717 8140

TR – Turkey,

 Istanbul

Tel: +90 216 4997081

[email protected]

TW – Taiwan,

 Taipei

Tel: +886 2 2298 8987

UA – Ukraine,

 Kiev

Tel: +380 44 494 2731

[email protected]

UK – United Kingdom,

 

Barnstaple

Tel: +44 (0)1271 313131

[email protected]

US – USA,

 Cleveland

Tel: +1 216 896 3000

VE – Venezuela,

 Caracas

Tel: +58 212 238 5422

ZA – South Africa,

 

Kempton Park

Tel: +27 (0)11 961 0700

[email protected]

European Product Information Centre
Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, EI, ES, FI, FR, IT, 
NL, NO, PL, RU, SE, SK, UK, ZA)

Содержание Phastite PH-10-4N-TMS

Страница 1: ...Phastite Tube Connectors Installation Manual BULLETIN 5909...

Страница 2: ...ocument are hereby offered for sale by Parker Hannifin Corporation its subsidiaries or its authorized distributors Any Order accepted by Parker Hannifin will be subject to our terms and conditions of...

Страница 3: ...the art machining centres and over 100 years of connector manufacturing has been utilised for accurate and consistent manufacturing of Phastite connectors Phastite is manufactured in Parker s facilit...

Страница 4: ...E C D Bore Tube O D A B1 D1 C1 D2 C2 B2 E2 E1 Tube O D 1 Bore Tube O D 2 F nE D Tube O D Bore E D B C A F A F D A C D G E Tube O D Bore E F A F D C B E Tube O D Bore A G A F F A F Thread Male E D C A...

Страница 5: ...ctors and hose assembly is called the tool assembly The system used to generate the hydraulic power for the tool assembly is called the pump Fail Safe Hose Assemblies and related connectors can and do...

Страница 6: ...ever using hydraulic equipment personal protective equipment PPE including eye protection hard hat gloves and steel toe boots should be utilized DANGER Never set the pump system relief valve to a high...

Страница 7: ...p or other means of safe transport Physical Damage WARNING Immediately replace worn or damaged parts with genuine Parker parts Phastite assembly equipment is manufactured from extreme service material...

Страница 8: ...the tube with the highest pressure rating to which it can be attached and is presented in Tables 1 to 4 The pressure rating of the tube has been calculated in accordance with ASME B31 3 Chemical Plan...

Страница 9: ...10 700 730 13 400 920 15 400 1060 10mm 3 800 260 4 600 310 5 900 400 7 300 500 8 300 570 9 200 630 12mm 3 100 210 3 800 260 4 800 330 5 900 400 6 700 460 7 500 510 16mm 2 300 150 2 800 190 3 500 240...

Страница 10: ...2 2 3 5 4 4 5 Stainless Steel 316 ASTM A269 6mm 1 4 6 600 450 8 200 560 9 130 630 9 130 630 9 130 630 10mm 1 4 3 800 260 4 600 310 5 900 400 7 300 500 8 300 570 9 130 630 10mm 3 8 3 800 260 4 600 310...

Страница 11: ...5 100 x 0 80 4 080 psi These factors are based on ASME B31 3 derating factors for ASTM A269 tubing They are derived from table A 1 basic allowable stresses in metals Note on selection The pressure rat...

Страница 12: ...and argon cannot be sealed with damaged tubing Make certain not to drag tubing across any surfaces such as truck beds shelves or storage racks the floor and or ground of any plant construction site Th...

Страница 13: ...Deburring the Tube End The burrs formed by either the tube cutter or hacksaw must be removed prior to assembly to prevent those burrs from eventually damaging the system O D burrs can prevent tubing f...

Страница 14: ...ure 7 Phastool 3A Tube O D Length Inches mm Inches mm 1 4 6 2 52 64 3 8 10 2 56 65 1 2 12 x x 5 8 16 x x 3 4 20 x x 1 25 x x Table 7 Table 8 Phastool 3B Tube O D Length Inches mm Inches mm 1 4 6 3 35...

Страница 15: ...the tubemarker around the tube enough pressure should be applied to create two visible lines The lines are easily visible once the tube has been removed from the tubemarker The tubemarker selected is...

Страница 16: ...Tool PH 16BT INSERT SHAPES PHT 16 6A PH 8 PE 1 2 12mm Phastool 3B PHT 3B 8S PHT 3B 8A RED Tri Tool PH 16BT INSERT SHAPES PHT 16 8A PH 10 PE 5 8 16mm Phastool 3B PHT 3B 10S PHT 3B 10A YELLOW Tri Tool...

Страница 17: ...PHT 16 12A BLUE PH 16 PT 1 25mm Tri Tool PH 16BT INSERT SHAPES PHT 16 16A GREEN Table 14 Figure 12 Part No Size Tool Fixed Jaw Moving Jaw Insert Colour Imperial Metric PH 4 PT 1 4 6mm Phastool 3A PHT...

Страница 18: ...G A F F A F Thread Male Part No Size Tool Fixed Jaw Moving Jaw Insert Color Imperial Metric PH 4 PC 1 4 6mm Phastool 3A PHT 3A 4A PHT 3A 4A GREY Phastool 3B PHT 3B 4A PHT 3B 4A Tri Tool PHT 16 4B PHT...

Страница 19: ...connector 3 Select the correct Phastool 4 Select the correct inserts 5 Select the pump type 6 Verify tube marking Figure 15 dimensions are in mm Tube Clearance Figure 16 A Minimum gap between Phastool...

Страница 20: ...16mm connections For the intermediate sizes of Phastite a larger portable tool is available for ease of installation The portable tool Figure 17 is supplied complete with a 12 ft 4 metre hose and qui...

Страница 21: ...d it can be used in any orientation however it is recommended that the supplied boot is used 1 Place and slide supplied boot onto the tool Figure 19 2 The boot has four mounting holes two on each side...

Страница 22: ...the hose to the tool s hydraulic inlet using the quick connect 4 Check all system fittings and connections to be sure they are tight and leak free 5 Link the digital touch screen controller to the pum...

Страница 23: ...onnections to be sure they are tight and leak free 7 Turn the mode wheel at the rear of the pump from CLOSE to OPEN Figure 32 and remove the mode wheel from the pump and Figure 33 the safety chain wil...

Страница 24: ...of connector to be assembled 6 Ensure that the connector is abutted against the insert in the fixed jaw 7 BOTTOM OUT THE TUBING Place the tubing into the tool and ensure positive engagement of the tub...

Страница 25: ...and there is metal to metal contact then a new connection new connector and new tubing is needed b Check for metal to metal contact visual If there is no metal to metal contact then a new connection...

Страница 26: ...hastite connector is completely assembled 4 WATCH FOR METAL TO METAL CONTACT Metal to metal contact is achieved when the Phastite collar and body are touching Figure 44 5 Once the Phastite connector i...

Страница 27: ...nders Selecting Inserts for the Tri Tool Installing Inserts on the Tri Tool 1 With the Tri Tool on a flat and stable work surface select the inserts needed each insert is colour coded and marked with...

Страница 28: ...nnect NOTE Ensure that the quick links provided are fastened between the hose containment hoops and mounting bracket there are 2 quick links for each end of the hose Figure 51 3 Check all system fitti...

Страница 29: ...5 6 If a termination connector is being installed insert and align the tube through the collar and sealing sleeve Please note that the marked tubing can also be inserted into the Phastite connector be...

Страница 30: ...collar movement Ensure sealing sleeve cone is protected from damage Tighten the collar onto the connector until the collar abuts fully with the body Tighten the nut until metal to metal contact is ach...

Страница 31: ...rs to hold the head of the top shaft while loosening the shaft nut Remove the nut from the top shaft Figure 62 2 The top shaft can now slide out of the tool Figure 63 3 There is now access to install...

Страница 32: ...received HCT provides a record of chemical analysis with the raw material HCT relieves the user of Parker instrumentation fittings of any doubts It acts as an assurance for today and for tomorrow In a...

Страница 33: ...41 42 Notes Notes...

Страница 34: ......

Страница 35: ...10 933 6450 parker greece parker com HK Hong Kong Tel 852 2428 8008 HU Hungary Budapest Tel 36 1 220 4155 parker hungary parker com IE Ireland Dublin Tel 353 0 1 466 6370 parker ireland parker com IN...

Отзывы: