35
*This procedure applies to the Tri-Tool
®
only.
1. Refer to pages 12-14 for tube marking instructions.
2. Refer to page 33 for Tri-tool
®
insert installation
instructions.
3. After selecting the connector and with the Tri-Tool on
a flat and stable work surface take a connector and
position between the fixed and moving jaw inserts. The
orientation will depend on the type of connector being
assembled. If a termination connector is being installed,
remove the collar and sealing sleeve (Figure 54).
4. Ensure the Phastite
®
connector is abutted against
either insert. Be sure to have proper orientation. Note:
On the Tri-Tool
®
the position of the moving jaw can be
moved manually to ensure insert retention of Phastite
®
connectors before the pump is actuated.
5. BOTTOM OUT THE TUBING.
Place the tubing into the
tool and ensure positive engagement of the tube grips.
Slide the tubing into the Phastite
®
connector ends. The
two lines produced by the tubemarker should not be
visible. This ensures adequate tube insertion prior to
assembly (Figure 55).
6. If a termination connector is being installed, insert and
align the tube through the collar and sealing sleeve.
*Please note that the marked tubing can also be inserted
into the Phastite
®
connector before being placed into
the tool.
7. If any lines are visible, it is an indication that either the tube
is not abutted correctly at the bottom of the Phastite
®
connector body or the tube was marked incorrectly.
8. Check again to ensure the tube is correctly inserted into
the Phastite
®
connector.
9. Once the tubing is correctly inserted into the Phastite
®
connector and no tubemarker lines are visible plug the
power lead into a mains socket and switch on, the
controller screen will turn on automatically. The operator
will be prompted to enter the 4-digit passcode assigned
to them upon successful completion of Parker SBEx
training (Figure 56).
10. Next, use the touch screen display to select from the
pump menu the option to suit the Phastite
®
connector to
be assembled (Figure 57).
11. You will be navigated to the pump’s main screen,
containing a digital pressure gauge, pump option, cycle
count, battery life, and a START/STOP button (Figure 58).
Figure 58
Figure 57
Figure 54
Installing the Connector with the Tri-Tool
®
Figure 55
Figure 56
Содержание Phastite PH-10-4N-TMS