background image

4601503-P1V-S  -  V4  -  August 2015

Your local authorized Parker distributor

© 2015 Parker Hannifin Corporation. All rights reserved.

Parker Hannifin Ltd.

 

Tachbrook Park Drive

Tachbrook Park, 

Warwick, CV34 6TU

United Kingdom 

Tel.:  +44 (0) 1926 317 878 

Fax: +44 (0) 1926 317 855

[email protected]

www.parker.com

Europe, Middle East, Africa

AE – United Arab Emirates, 

Dubai 
Tel:  +971 4 8127100 
[email protected]

AT – Austria, 

Wiener Neustadt 

Tel:  +43 (0)2622 23501-0 
[email protected]

AT – Eastern Europe, 

Wiener 

Neustadt 
Tel: +43 (0)2622 23501 900 
[email protected]

AZ – Azerbaijan, 

Baku 

Tel: +994 50 2233 458 
[email protected]

BE/LU – Belgium, 

Nivelles 

Tel: +32 (0)67 280 900 
[email protected]
BG 

 Bulgaria, Sofia 

Tel: +359 2 980 1344 
[email protected]

BY – Belarus, 

Minsk 

Tel: +48 (0)22 573 24 00 
[email protected]

CH – Switzerland, 

Etoy 

Tel: +41 (0)21 821 87 00  
[email protected]

CZ – Czech Republic, 

Klecany 

Tel: +420 284 083 111 
[email protected]

DE – Germany, 

Kaarst 

Tel: +49 (0)2131 4016 0 
[email protected]

DK – Denmark, 

Ballerup 

Tel: +45 43 56 04 00 
[email protected]

ES – Spain, 

Madrid 

Tel: +34 902 330 001 
[email protected]

FI – Finland, 

Vantaa 

Tel: +358 (0)20 753 2500 
[email protected]

FR – France, 

Contamine s/Arve 

Tel: +33 (0)4 50 25 80 25 
[email protected]

GR – Greece, 

Athens 

Tel: +30 210 933 6450 
[email protected]

HU – Hungary, 

Budaörs 

Tel: +36 23 885 470 
[email protected]

IE – Ireland, 

Dublin 

Tel: +353 (0)1 466 6370 
[email protected]

IT – Italy, 

Corsico (MI) 

Tel: +39 02 45 19 21 
[email protected]

KZ – Kazakhstan,

 Almaty 

Tel: +7 7273 561 000 
[email protected]

NL – The Netherlands, 

Oldenzaal 

Tel: +31 (0)541 585 000 
[email protected]

NO – Norway, 

Asker 

Tel: +47 66 75 34 00 
[email protected]

PL – Poland, 

Warsaw 

Tel: +48 (0)22 573 24 00 
[email protected]

PT – Portugal, 

Leca da Palmeira 

Tel: +351 22 999 7360 
[email protected]

RO – Romania, 

Bucharest 

Tel: +40 21 252 1382 
[email protected]

RU – Russia, 

Moscow 

Tel: +7 495 645-2156 
[email protected]

SE – Sweden, 

Spånga 

Tel: +46 (0)8 59 79 50 00 
[email protected]

SK – Slovakia, 

Banská Bystrica

 

Tel: +421 484 162 252 
[email protected]

SL – Slovenia, 

Novo Mesto 

Tel: +386 7 337 6650 
[email protected]

TR – Turkey, 

Istanbul 

Tel: +90 216 4997081 
[email protected]

UA – Ukraine, 

Kiev 

Tel: +48 (0)22 573 24 00 
[email protected]

UK – United Kingdom, 

Warwick 

Tel: +44 (0)1926 317 878 
[email protected]

ZA – South Africa, 

Kempton Park 

Tel: +27 (0)11 961 0700 
[email protected]

North America

CA – Canada, 

Milton, Ontario 

Tel: +1 905 693 3000

US – USA, 

Cleveland  

Tel: +1 216 896 3000

Asia Pacific

AU – Australia, 

Castle Hill 

Tel: +61 (0)2-9634 7777

CN – China, 

Shanghai 

Tel: +86 21 2899 5000

HK – Hong Kong 

Tel: +852 2428 8008

IN – India, 

Mumbai 

Tel: +91 22 6513 7081-85

JP – Japan, 

Tokyo 

Tel: +81 (0)3 6408 3901

KR – South Korea, 

Seoul 

Tel: +82 2 559 0400

MY – Malaysia, 

Shah Alam 

Tel: +60 3 7849 0800

NZ – New Zealand, 

Mt Wellington 

Tel: +64 9 574 1744

SG – Singapore 

Tel: +65 6887 6300

TH – Thailand, 

Bangkok 

Tel: +662 186 7000

TW – Taiwan, 

Taipei 

Tel: +886 2 2298 8987

South America

AR – Argentina, 

Buenos Aires 

Tel:  +54 3327 44 4129

BR – Brazil, 

Sao Jose dos Campos 

Tel: +55 800 727 5374 

CL – Chile, 

Santiago

 

Tel: +56 2 623 1216

MX – Mexico, 

Toluca 

Tel: +52 72 2275 4200

Parker Worldwide

European Product Information Centre
Free phone: 00 800 27 27 5374
(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, 
FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, 
SE, SK, UK, ZA)

Содержание P1V-S

Страница 1: ...the surrounding area Important instructions relating to explosion protection Application tips and other useful information Definition Potentially explosive atmosphere hereinafter referred to as Ex are...

Страница 2: ...apply Warranty and liability claims in regards to persons or equipment damage are invalid if one or several of the following causes apply Use of the equipment in a non designated application Improper...

Страница 3: ...erature of 135 C Motor should be tested to ensure that the permissible temperature does not exceed 130 C there is a safety margin of 5 C This is the maximum permissible surface temperature of the moto...

Страница 4: ...utch etc have to be covered by a contact guard 8 8 0 72 1 28 2 9 5 75 9 9 24 48 83 132 200 275 390 10 9 1 02 1 8 4 1 8 1 14 34 67 117 185 285 390 550 12 9 1 21 2 15 4 95 9 7 16 5 40 81 140 220 340 470...

Страница 5: ...make sure that the flow pressure at the motor connection side is 6 bar 85 PSI A higher air pressure leads to increased wear and tear install a pressure regulator An air pressure below 6 bar reduces t...

Страница 6: ...ure in accordance 5 3 with requirements Has it been certified that the air motor is sufficiently ventilated and that there is no 5 5 additional warming source such as a clutch I This check list shows...

Страница 7: ...for the disassembly original spare parts and the trained repair specialists that can adjust the air motor to the correct gap play The gap play determines the motors power efficiency and life expectanc...

Страница 8: ...t be changed Continuous lubrication free operation of motors equipped with vanes option C Duty cycle Continuous Filtering 40 m 750 hours of operation Filtering 5 m 1 000 hours of operation The specifi...

Страница 9: ...operation For motors Order code P1V S002A P1V 6 446083A P1V S003A P1V 6 446083A P1V S008A P1V 6 446084A P1V S012A0 D0 to serial no 948688 9121720601 P1V S012A0 D0 from serial no 948689 9121720636 P1V...

Страница 10: ...0620 P1V S120A 110 9121720620 P1V S120A 078 9121720621 P1V S120A 032 9121720621 P1V S120A 012 9121720621 Service kits for brake module for motors with brakes For motors Order code P1V S020AD and P1V S...

Страница 11: ...1V S motors carry the CE mark because they are ATEX certified for use in explosive atmospheres The following are the currently applicable directives Machinery Directive essential health and safety req...

Страница 12: ...and of motor bearing cover Air pressure is Increase air too low pressure No air shut off Open shut off valve is closed valve Hose diameter Use a hose with a is too small larger diameter Exhaust air i...

Страница 13: ...s the ambient temperature as specified in the technical data in the catalogue at all times 3 Are you certain that the P1V S motor is adequately ventilated and that no additional heat is added for exam...

Страница 14: ...eich clamping area 119 13 5 17 e8 17 11 5 3 5 6 5 4 k6 10 8 e8 1 1 measuring point for temperature measurement Motor P1V S002A0130 Motor P1V S002A0095 Motor P1V S008A0190 Motor P1V S008A0130 1 measuri...

Страница 15: ...5 K 80 C Maximum permitted surface temperature on the motor in atmospheres containing potentially explosive dust X Note special conditions Test certificate number IBExU04ATEXB004 X from IBExU Institu...

Страница 16: ...0 parker easteurope parker com NL The Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00...

Отзывы: