5.  Assembly Instructions

Perform all assembly, installation, maintenance and 
repair work outside of the Ex-area. 

5.1  Prior to Installation

The air motor should only be installed if:

•  the details of the motor tag correspond with the details  
  of the potentially explosive athmosphere of use (design  
  group, design category, Ex-area, temperature class,  
  maximum surface temperature).
•  it is undamaged.
•  it was verified that no explosive atmospheres, oils,  
  acids, gases, steams or radiation, occurred during  
 installation. 

5.2 Pre-Installation

Drive shafts and flange areas should always be free from 
anticorrosive solvents, dirt or other agents. Solvents 
should not be allowed to penetrate the gear seal ring – 
this may cause material damage! 
To avoid a swelling of the seal rings and damage to 
internal parts of the air motor, use only solvents approved 
by Parker (such as HAKU 1025-810-1 cold cleaner).  Seal 
material: NBR/FKM

5.3  Operating Pressure and Temperature Range

Operating Pressure 

Maximum operating pressure: 6 bar / 85 PSI 

Temperature Range  

Ambient temperature at standard operating
(outside Ex-area): -20°C to +110°C

Ambient temperature for use in Ex-area: -20 °C to + 40 °C

Compressed Air Temperature  

The temperature of the compressed air used may not 
exceed the ambient temperature requirements.

If ambient temperatures are different, please contact 
Parker.

5.4  Installation Instructions

Important Notes for  Installation of Motor 

•  Install the motor according to the dimension sheet  
  (see chapter 5.6).
•  The air motor may be installed in any orientation.
•  Non-reversible air motors have a right or left rotational  
  direction (as seen from air inlet in the direction to the  
 drive.
•  Use only mounting brackets having a sufficient size.
•  Use only the implemented mounting holes to fixture the  
  air motor.
•  Observe the tightening torques for the mounting screws  
  (see table 1).
•  A maintenance unit should be installed
  (see illustration „Diagram“ in chapter 5.7).
•  Be especially careful with all rotating parts.
•  Do not install a belt pulley, clutch or pinion to the   
  shaft-end, using ham-mer blows; this will damage  
  gears, housing and shaft.
•  Use an extractor for disassembly.
•  Do not exceed the permissible radial and axial forces of  
  the shaft (see chapter 4.2).
Attachment of the drive element will be simplified if a 
lubricant is applied or when heated-up for a moment – 
prior to installation (to 80°C to 100°C).
Drive attachments, such as a belt pulley, clutch, etc. have 
to be covered by a contact guard.

 

8.8  0.72 1.28 2.9 5.75 9.9  24  48  83  132 200 275 390

 10.9  1.02 1.8  4.1  8.1  14  34  67  117 185  285 390  550

 12.9  1.21 2.15 4.95 9.7  16.5  40  81  140 220  340 470  660

 70*  0.46 0.82  1.9  3.7  6.4 15.3  31  52  83  126 174  245

M 2.5

M 3

M 4

M 5

M 6

M 8

M 10

M 12

M 14

M 16

M 18

M 20

Pr

operty

Class

Tightening torque (Nm) for thread ...

Use screws of property class (min.) 8.8 or 70 for stainless 
screws in order to mount the air motor onto your machine. 

* for stainless screws

Table 1 – Tightening torques for mounting screws

5.5  Additional Instructions for Installation in an  
 

Explosive Hazardous Area

Grounding

The air motor must be grounded, for example by using
•  an air-supply line made of metal or
•  an electrically conductive hose.
The resistance between motor and ground has to be 
measured (requirement: <10

6

 Ω).

Only use drive attachments that correspond to gui-
deline 2014/34/EU.

 Only use belts in the Ex-area, which 

correspond to the guideline 2014/34/EU (among others, 
items to watch is the belts electric conductivity and the 
correct belt-tension, since either may generate heat due  
to slippage). 
The explosion-proof air motors correspond to the design 
requirements of the design group II, category 2 GD (explo-
sive atmosphere consisting of gas and dust).  
Those motors are suited for the installation into Zone 1 
and Zone 21.

Temperature Class

The air motors of group II, category 2 GD are suitable for 
the temperature class: T6, TS ov T4

Surface Temperature

This corresponds to a maximum surface temperature of:  
80, 95 ov 130 °C

Protection Class 

All air motors must correspond – for a minimum – with the 
standard EN 60529 of the protection class IP 54. They are 
designed for the use in dusty or damp environments. 

Ambient Conditions

Make sure that the air motor is sufficiently ventilated and 
that there is no  additional warming source (such as a 
clutch).
Open inlet and exhaust ports are not permissible. Those 
type of ports have to be closed, using either a sintered-
metal filter (optional equipment) or an airline. If an airline 
is installed to any of the open ports (without the use of a 
sintered-metal filter), then they have to be guided out of 
the Ex-area.

Drive Power and Torque 

Do not exceed either the maximum permissible drive 
power, or the maximum allowable radial and axial forces.

Braking Mode 

The air motors may not be used in a braking mode in 
the Ex-area. 

 A braking mode is when the motor is 

operated opposite to the turn-direction of the air-supply; 
this will have the motor operate as a compressor. 

Always follow the safety instructions of chapter 2.5 while installing an air 
motor into an Ex-area.

Содержание P1V-S

Страница 1: ...the surrounding area Important instructions relating to explosion protection Application tips and other useful information Definition Potentially explosive atmosphere hereinafter referred to as Ex are...

Страница 2: ...apply Warranty and liability claims in regards to persons or equipment damage are invalid if one or several of the following causes apply Use of the equipment in a non designated application Improper...

Страница 3: ...erature of 135 C Motor should be tested to ensure that the permissible temperature does not exceed 130 C there is a safety margin of 5 C This is the maximum permissible surface temperature of the moto...

Страница 4: ...utch etc have to be covered by a contact guard 8 8 0 72 1 28 2 9 5 75 9 9 24 48 83 132 200 275 390 10 9 1 02 1 8 4 1 8 1 14 34 67 117 185 285 390 550 12 9 1 21 2 15 4 95 9 7 16 5 40 81 140 220 340 470...

Страница 5: ...make sure that the flow pressure at the motor connection side is 6 bar 85 PSI A higher air pressure leads to increased wear and tear install a pressure regulator An air pressure below 6 bar reduces t...

Страница 6: ...ure in accordance 5 3 with requirements Has it been certified that the air motor is sufficiently ventilated and that there is no 5 5 additional warming source such as a clutch I This check list shows...

Страница 7: ...for the disassembly original spare parts and the trained repair specialists that can adjust the air motor to the correct gap play The gap play determines the motors power efficiency and life expectanc...

Страница 8: ...t be changed Continuous lubrication free operation of motors equipped with vanes option C Duty cycle Continuous Filtering 40 m 750 hours of operation Filtering 5 m 1 000 hours of operation The specifi...

Страница 9: ...operation For motors Order code P1V S002A P1V 6 446083A P1V S003A P1V 6 446083A P1V S008A P1V 6 446084A P1V S012A0 D0 to serial no 948688 9121720601 P1V S012A0 D0 from serial no 948689 9121720636 P1V...

Страница 10: ...0620 P1V S120A 110 9121720620 P1V S120A 078 9121720621 P1V S120A 032 9121720621 P1V S120A 012 9121720621 Service kits for brake module for motors with brakes For motors Order code P1V S020AD and P1V S...

Страница 11: ...1V S motors carry the CE mark because they are ATEX certified for use in explosive atmospheres The following are the currently applicable directives Machinery Directive essential health and safety req...

Страница 12: ...and of motor bearing cover Air pressure is Increase air too low pressure No air shut off Open shut off valve is closed valve Hose diameter Use a hose with a is too small larger diameter Exhaust air i...

Страница 13: ...s the ambient temperature as specified in the technical data in the catalogue at all times 3 Are you certain that the P1V S motor is adequately ventilated and that no additional heat is added for exam...

Страница 14: ...eich clamping area 119 13 5 17 e8 17 11 5 3 5 6 5 4 k6 10 8 e8 1 1 measuring point for temperature measurement Motor P1V S002A0130 Motor P1V S002A0095 Motor P1V S008A0190 Motor P1V S008A0130 1 measuri...

Страница 15: ...5 K 80 C Maximum permitted surface temperature on the motor in atmospheres containing potentially explosive dust X Note special conditions Test certificate number IBExU04ATEXB004 X from IBExU Institu...

Страница 16: ...0 parker easteurope parker com NL The Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00...

Отзывы: