15
www.parker.com/euro_pneumatic
Marking of products
C
ommunatuté
E
uropéenne = EU
CE
marking shows that as a manufacturer, Parker Han-
nifin meets the guidelines specified by the EU
Ex
means that this product is intended for use in a po-
tentially explosive area
II
stands for the equipment group (I = mines and II = other
places liable to be endangered)
2GD
stands for equipment category
2G
means the equipment can be used in zones 1 and
2 where there is a risk involving gas, vapour or mist of
combustible liquids and
2D
in zones 21 and 22 where
there is a risk involving dust .
2GD
means the equipment can be used in zones
1, 2, 21 and 22.
c
Safe design (prEN 13463-5)
IIC
Explosion group, P1V-S air motors are tested to the hig-
hest standards in terms of test gases, and can be instal-
led in the presence of all gases without
restriction.
T6
If equipment is in temperature class
T6
, the maximum
surface temperature must not exceed 85 °C.
(To guarantee this, the product has been tested to
ensure that the maximum is 80 °C. This provides a sa-
fety margin of 5 °K.)
T5
If equipment is in temperature class
T5
, the maximum
surface temperature must not exceed 100 °C. (To gua-
rantee this, the product has been tested to
ensure
that the maximum is 95 °C. This provides a safety mar-
gin of 5 °K.)
(80 °C)
Maximum permitted surface temperature on the motor
in atmospheres containing potentially explosive dust.
X
Note special conditions
Test certificate number IBExU04ATEXB004 X from
IBExU Institut für Sicherheitstechnik GmbH, D-09599
Freiberg, Germany
The temperature is measured on the metal surface next to the
seal around the output shaft on all P1V-S012, P1V-S020,
P1V-S028, P1V-S030, P1V-S057, P1V-S060, P1V-S086 and
P1V-S090 motors.
II2 GD c IIC T6 (80 °C) X
II2 GD c IIC T5 (95 °C) X
Seal
Planetary gearbox
Motor part
45
Motor part
x
Motor
x [mm]
P1V-S030A0023
146
P1V-S030A0010
147,5
The maximum temperature is reached after approximately 1.5
hours of operation, and the difference in temperature between
the motor and the ambient temperature must not exceed 40 °C.
If the temperature difference at the seal of a P1V-S 120 to
900 watts exceeds 40 °C, you should stop the motor
immediately and contact Parker Hannifin.
The following applies to the P1V-S120 series:
The temperature is measured on the metal surface at a point 45
mm from the port end of the motor housing, on all P1V-S120.
Motors P1V-S030A0023 and P1V-S030A0010
The maximum temperature is reached after approximately 1.5
hours of operation and the difference in temperature between the
motor and the ambient temperature must not exceed 55 °C.
If the temperature difference at this point on a P1V-S120
exceeds 55 °C, you should stop the motor immediately
and contact Parker Hannifin.
Planetary gearbox