background image

PARKER WORLDWIDE

AE – UAE, 

Dubai

Tel: +971 4 8127100
[email protected]

AR – ARGENTINA, 

Buenos Aires

Tel: +54 3327 44 4129

AT – AUSTRIA

Wiener Neustadt

Tel: +43 (0)2622 23501-0
[email protected]

AT – EASTERN EUROPE,

Wiener Neustadt
Tel: +43 (0)2622 23501 900
[email protected]

AU – AUSTRALIA,

 Castle Hill

Tel: +61 (0)2-9634 7777

AZ – AZERBAIJAN,

 Baku

Tel: +994 50 2233 458
[email protected]

BE/LU – BELGIUM,

 Nivelles

Tel: +32 (0)67 280 900
[email protected]

BR – BRAZIL, 

Cachoeirinha RS

Tel: +55 51 3470 9144

BY – BELARUS, MINSK

Tel: +375 17 209 9399
[email protected]

CA – CANADA,

 Milton, Ontario

Tel: +1 905 693 3000

CH – SWITZERLAND

, Etoy

Tel: +41 (0)21 821 87 00
[email protected]

CL – CHILE,

 Santiago

Tel: +56 2 623 1216

CN – CHINA,

 Shanghai

Tel: +86 21 2899 5000

CZ – CZECH REPUBLIC,

 Klecany

Tel: +420 284 083 111
[email protected]

DE – GERMANY,

 Kaarst

Tel: +49 (0)2131 4016 0
[email protected]

DK – DENMARK,

 Ballerup

Tel: +45 43 56 04 00
[email protected]

ES – SPAIN, 

Madrid

Tel: +34 902 330 001
[email protected]

FI – FINLAND,

 Vantaa

Tel: +358 (0)20 753 2500
parker.fi  [email protected]

FR – FRANCE, 

Contamine s/Arve

Tel: +33 (0)4 50 25 80 25
[email protected]

GR – GREECE,

 Athens

Tel: +30 210 933 6450
[email protected]

HK – 

Hong Kong

Tel: +852 2428 8008

HU – HUNGARY,

 Budapest

Tel: +36 1 220 4155
[email protected]

IE – IRELAND,

 Dublin

Tel: +353 (0)1 466 6370
[email protected]

IN – INDIA

, Mumbai

Tel: +91 22 6513 7081-85

IT – ITALY, 

Corsico (MI)

Tel: +39 02 45 19 21
[email protected]

JP – JAPAN,

 Tokyo

Tel: +81 (0)3 6408 3901

KR – SOUTH KOREA,

 Seoul

Tel: +82 2 559 0400

KZ – KAZAKHSTAN,

 Almaty

Tel: +7 7272 505 800
[email protected]

LV – LATVIA,

 Riga

Tel: +371 6 745 2601
[email protected]

MX – MEXICO,

 Apodaca

Tel: +52 81 8156 6000

MY – MALAYSIA,

 Shah Alam

Tel: +60 3 7849 0800

NL – 

Th

 e Netherlands,

Oldenzaal
Tel: +31 (0)541 585 000
[email protected]

NO – NORWAY,

 Asker

Tel: +47 66 75 34 00
[email protected]

NZ – NEW ZEALAND,

 Mt Wellington

Tel: +64 9 574 1744

PL – POLAND,

 Warsaw

Tel: +48 (0)22 573 24 00
[email protected]

PT – PORTUGAL,

 Leca da Palmeira

Tel: +351 22 999 7360
[email protected]

RO – ROMANIA,

 Bucharest

Tel: +40 21 252 1382
[email protected]

RU – RUSSIA,

 Moscow

Tel: +7 495 645-2156
[email protected]

SE – SWEDEN

, Spånga

Tel: +46 (0)8 59 79 50 00
[email protected]

SG

 – Singapore

Tel: +65 6887 6300

SK – SLOVAKIA

, Banská Bystrica

Tel: +421 484 162 252
[email protected]

SL – SLOVENIA

, Novo Mesto

Tel: +386 7 337 6650
[email protected]

TH – THAILAND, 

Bangkok

Tel: +662 717 8140

TR – TURKEY, 

Istanbul

Tel: +90 216 4997081
[email protected]

TW – TAIWAN, 

Taipei

Tel: +886 2 2298 8987

UA – UKRAINE, 

Kiev

Tel +380 44 494 2731
[email protected]

UK – UNITED KINGDOM

,

Warwick
Tel: +44 (0)1926 317 878
[email protected]

US – USA, 

Cleveland

Tel: +1 216 896 3000

VE – VENEZUELA, 

Caracas

Tel: +58 212 238 5422

ZA – SOUTH AFRICA,

Kempton Park
Tel: +27 (0)11 961 0700
[email protected]

41

N2 Compact Nitrogen Gas Generator - User Guide. ©2020.

European Product 
Information Centre

Free phone: 00 800 27 27 5374

(from AT, BE, CH, CZ, DE, EE, 
ES, FI, FR, IE, IL, IS, IT, LU, MT, 
NL, NO, PT, SE, SK, UK)

Содержание N2 NITROSource Compact N2C-2

Страница 1: ...NITROGEN GAS GENERATOR NITROSource Compact USER GUIDE 17 651 1000 01 20 Rev Preventative Maintenance Guide 17 651 1100 User Guide EN N2C 2 N2C 4 N2C 6 N2C 8 N2...

Страница 2: ...e Generator Stopping the Generator Fault Log Customer Settings Overview of the Controls Menu Interface Hour Meters Generator Supply Dryer Supply Purge Economy Remote Switching Overview of the Equipmen...

Страница 3: ...let Parameters Environmental Parameters Port Connections Electrical Parameters Packed Weights and Dimensions Troubleshooting Schematics Generator Weights and Dimensions Declaration of Conformity Techn...

Страница 4: ...04 N2 Compact Nitrogen Gas Generator User Guide 2020 SAFETY...

Страница 5: ...ent is high such as a confined space or poorly ventilated room the use of oxygen monitoring equipment is advisable Nitrogen is not a poisonous gas but in a concentrated form there is a risk of asphyxi...

Страница 6: ...AMMABLE COMPRESSED GAS Wear ear protection Pressurised components on the system Remote control Generator may start automatically without warning Conformit Europ enne Dispose in accordance with local r...

Страница 7: ...07 N2 Compact Nitrogen Gas Generator User Guide 2020 RECEIVING AND INSPECTING THE EQUIPMENT...

Страница 8: ...ase inform the delivery company immediately and contact your local Parker office STORAGE The equipment should be stored within the packing crate in a clean dry environment If the crate is stored in an...

Страница 9: ...ng the generator to the base of the crate 02 Lift the generator from the pallet using suitable slings and an overhead crane 03 Carefully move the generator to its final location using a forklift truck...

Страница 10: ...10 N2 Compact Nitrogen Gas Generator User Guide 2020 OVERVIEW OF THE EQUIPMENT...

Страница 11: ...e N2 Outlet port to buffer G Column B pressure gauge Air inlet pressure gauge Mains supply cable gland N2 inlet port from buffer vessel G Air Inlet port G N2 Outlet pressure gauge Cable glands N2 Outl...

Страница 12: ...12 N2 Compact Nitrogen Gas Generator User Guide 2020 LOCATING THE EQUIPMENT...

Страница 13: ...metre of compressed air the particulate count should not exceed 400 000 particles in the 0 1 0 5 micron size range 6 000 particles in the 0 5 1 micron size range and 100 particles in the 1 5 micron s...

Страница 14: ...14 N2 Compact Nitrogen Gas Generator User Guide 2020 INSTALLATION AND COMMISSIONING...

Страница 15: ...Generator User Guide 2020 Warning Only competent personnel trained qualified and approved by Parker should perform installation commissioning service and repair procedures REF REF REF REF DESCRIPTION...

Страница 16: ...NB 16mm ID piping between the ball valve and the outlet port of the buffer vessel The AOP010 filter provided should be installed in this line Follow the installation instructions provided with the fi...

Страница 17: ...te switching is activated in the customer settings menu MODBUS For MODBUS communicatin setup details refer to publication 17 650 0012 6 12 mm 3 7 mm 3 7 mm 3 7 mm 3 7 mm L Fuse terminal for the phase...

Страница 18: ...itional information on installation requirements If the pre treatment dryer is fitted with a purge economy feature it may be controlled using the volt free relay contacts on JP17 The relay is energise...

Страница 19: ...D is set to 6 Note The oxygen purity setting of the generator is marked on the rating plate The table below shows the correlation between the purity settings of the generator and the output current Th...

Страница 20: ...20 N2 Compact Nitrogen Gas Generator User Guide 2020 OPERATING THE GENERATOR...

Страница 21: ...SCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION Start key Operating status indicator Green Running Yellow Starting up Shutting down Red Standby Menu navigation keys Service Fault indicator Yellow Servic...

Страница 22: ...l this cycle is complete and the menu displays Running This may take several minutes for ppm generators 6 Partially open the ball valve on the inlet to the buffer vessel to allow it to pressurise slow...

Страница 23: ...ime in hours that the generator has been operating in Economy mode O2 5 00 O2 5 00 Shutting Down Shutting Down 1 Hour meters 1 Hour meters 2 Fault log 2 Fault log 2 1 Fault 10 2 1 Fault 10 2 1 Fault 1...

Страница 24: ...n the system Note Any faults that are active when the power is switched off and remain active when the power is re applied will cause a new entry to be added into the fault log 2 1 Fault 1 Active 2 1...

Страница 25: ...mpact Nitrogen Gas Generator User Guide 2020 3 1 O2 Alarm 3 1 O2 Alarm Over ride 0 Over ride 0 3 2 O2 Calibration 3 2 O2 Calibration 5 00 5 00 3 3 O2 Alarm Level 3 3 O2 Alarm Level 5 05 5 05 3 4 O2 Al...

Страница 26: ...se The generator will continue to cycle as normal without delivering gas to the application If the back pressure is maintained for an additional 5 minutes the generator will stop cycling and enter Eco...

Страница 27: ...27 N2 Compact Nitrogen Gas Generator User Guide 2020 SERVICING THE GENERATOR...

Страница 28: ...hs 24 Months Generator Check status indicators located on the control panel Generator Check regulated outlet pressure Generator Check O2 purity System Check filter drains System Check inlet air qualit...

Страница 29: ...P010AO element Catalogue No s Description Contents M24 PPM 0002 Kit 02 Cell PPM 02 Cell PPM M24 PCT 0002 Kit 02 Cell 02 Cell Catalogue No s Description Contents M24 N2C 0001 Kit 24 Month N2C valve ove...

Страница 30: ...retaining screw 06 of the assembly and remove Cut the tie wrap and unscrew the oxygen sensor Remove the used cell and replace with the new one Note Ensure to wear gloves when handling the new cell to...

Страница 31: ...tering the calibrated level USING A CALIBRATED GAS SUPPLY Select menu 3 1 and enable the O Alarm Over ride Connect the gas supply to the O Analyser calibration port 1 on the side of the generator Loca...

Страница 32: ...ul the original reading from the analyser will be loaded Should this occur repeat the above steps On completion of the calibration return the ball valves back to their original position and remove the...

Страница 33: ...Note A strap wrench may be required for the removal of the 050 055 filter bowl Close the ball valves located on the inlet and outlet ports of the filter and depressurise it by opening the manual drai...

Страница 34: ...cated in the filter head with the new O ring provided Refit the filter bowl and head ensuring that the threads are fully engaged 01 and the locking details are aligned 02 Note To ensure that the bowl...

Страница 35: ...35 N2 Compact Nitrogen Gas Generator User Guide 2020 TECHNICAL SPECIFICATION...

Страница 36: ...trol system automatically switches the bed to regenerative mode All of the contaminants are vented from the CMS and a small portion of the outlet nitrogen gas is expanded into the bed to accelerate th...

Страница 37: ...8 11 0 13 3 15 3 17 1 N2C 8 M3 HR 3 38 5 89 10 24 14 86 18 01 24 02 29 33 33 93 37 81 CFM 2 0 3 5 6 0 8 7 10 6 14 1 17 3 20 0 22 3 Air to N2 N2C 2 to N2C 8 7 0 5 3 3 9 3 2 3 0 2 5 2 3 2 1 2 0 Outlet P...

Страница 38: ...e generator alone and does not take in to account any pre treatment dryer connected to the dryer supply terminals of the generator The dryer is fed directly from the generator supply PACKED WEIGHTS AN...

Страница 39: ...4 19 207 5 8 17 237 5 9 35 98 216 1 N2C 4 1040 40 9 450 18 628 27 72 375 14 76 466 5 18 37 406 5 16 681 5 26 83 753 5 29 66 868 5 34 19 207 5 8 17 237 5 9 35 145 319 7 N2C 6 1040 40 9 450 18 796 31 34...

Страница 40: ...erform the required service High Oxygen concentration Defective Oxygen cell Replace the oxygen cell Leak in system piping Open the access door and check all connection points for leaks Repair as neces...

Страница 41: ...ALY Corsico MI Tel 39 02 45 19 21 parker italy parker com JP JAPAN Tokyo Tel 81 0 3 6408 3901 KR SOUTH KOREA Seoul Tel 82 2 559 0400 KZ KAZAKHSTAN Almaty Tel 7 7272 505 800 parker easteurope parker co...

Страница 42: ...rformance is maintained Air quality continues to meet international standards Protection of downstream equipment personnel and processes Low operational costs Increased productivity and profitability...