2. Object index
Interbus-S
70
2.12.2
PED_Steuerung
The process input data can be used to cyclically read from the following COMPAX communication objects.
Object name
Description
Index
COMPAX -
Parameter
Byte
see
dec
hex
P135 ... P138
Number
page
STATUSBYTE
Status byte
24527
0x5fcf
1
STATUSWORT
Status word
24641
0x6041
2
CPX_ZSW
COMPAX status word
24531
0x5fd3
2
LAGE_IST
Actual position value
24676
0x6064
4
INPUT_WORD
Log. state of the 16 dig. inputs
24568
0x5ff8
2
OUTPUT_WORD
Log. state of the 16 dig. outputs
24567
0x5ff7
2
S3
Lag error
24570
0x5ffa
2
S4
Current traverse speed
24572
0x5ffc
2
S5
Current motor torque
24571
0x5ffb
2
OBJECT_RSP
COMPAX – answer to OBJECT_REQ
24518
0x5fc6
6276608
6
Because the PED channel has a max length of 8 byte, it is not possible to read all listed objects simultaneously. This means you
need to make an appropriate selection.
Setting the PED
!
via the object "Process Input Data Description",
or
!
via the COMPAX parameters P135, P136, P137, P138 (corresponds to the object PED_INI).
You may place each of the named objects on the PED channel according to its required bytes.
Set the corresponding COMPAX parameter to the value given for the respective object (see table above).
Length
Possible assignment in the PED channel
in byte
PED1
PED2
PED3
PED4
PED5
PED6
PD-Length=8Byte
(P196 Bit 0...2="4")
PED3
PED4
PED5
PED6
PED7
PED8
Object:
P135
P136
P137
P138
STEUERBYTE
1
STATUSWORT
2
CPX_ZSW
2
S3
2
S4
2
S5
2
INPUT_WORD
2
OUTPUT_WORD
2
LAGE_IST
4
OBJECT_RSP
6
Ensure that there is no double assignment in the PED channel.
Double assignment occur when e.g. LAGE_IST is on PED1 - PED4 and a further assignment of PED3 (5) is undertaken
via P137.
The proper action in this case would be: POSITION_ACTUAL to PED1 - PED4 using P135 = 6317056 and P136 = P137
= 0!
4 Index * 256 + Sub-index
Содержание Hauser COMPAX-M Series