2.4
Control
2.4.3
STEUERBYTE
17
2.4.3 STEUERBYTE
Allows program start from record 1 - 15.
The record pointer is set to the corresponding program record.
The program can be started, stopped, and continued.
"
The machine zero is approached with the record selection = "0000" and "Start".
An error acknowledgement is possible.
Object Description
Index
0x5FCE
Symbol
STEUERBYTE
Length
1
Access groups
0
Object code
Simple var.
Password
0
Data type
Octet String
Access rights
Read/write all
PD Map
PAD
Data Description
Data byte [Bit]
Assignment
Meaning
1 [7]
Quit (not when P190=22)
Error acknowledge with a positive edge
1 [6]
Stop with ramp P10 without clearing
with a positive edge
1 [5]
Continue ("1") / new start ("0") with Start
Continue:
Continue program
New start:
Prog. start at selected record
1 [4]
Start / Stop
#
Start after the response defined in Bit 5
$
Stop
1 [3]
Record select (2
3
)
Note!
1 [2]
Record select (2
2
)
With the record selection = "0000" and "New start",
1 [1]
Record select (2
3
)
the machine zero point is approached
1 [0]
Record select (2
0
)
The "Quit" command is not accepted for P190=22 (DRIVECOM profile 22) (Error message aknowledgement as outlined
in the status chart on page 77).
2.4.4 STATUSBYTE
The status byte shows information about the status of the device as well as messages.
Object Description
Index
0x5FCF
Symbol
STATUSBYTE
Length
1
Access groups
0
Object code
Simple var.
Password
0
Data type
Octet String
Access rights
Read all
PD Map
PED
Data Description
Data byte [Bit]
Assignment
1 [7]
Machine zero point approached
1 [6]
Idle after stop
1 [5]
Programmed nominal position reached
1 [4]
Motor stalled
1 [3]
Lag error
1 [2]
Ready for start (see below)
1 [1]
Warning
1 [0]
Fault
Meaning of "Ready for Start"
"Ready for Start" is used to control the program and is set
%
when the program is halted by a WAIT START instruction
and is waiting for the START signal.
%
after an interruption with STOP or BREAK and these
signals no longer occur.
%
after a rectified error.
%
after power on.
%
at the program end with the command END.
"Ready for Start" has no meaning when commands are input
directly.