2. Object index
Interbus-S
22
2.4.10
CONTROL
Control commands. Compax commands which do not require additional values.
The required commands are activated by reading in the relevant command number.
Object Description
Index
0x5fe9
Symbol
CONTROL
Length
1
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned8
Access rights
write all
PD Map
PAD
Data Description
Comma
nd no.
Function
Comman
d No.
Function
1
Go to machine home
12
Drive dead with opened brake
2
Program start
13
Program jump via external inputs
3
Stop program/positioning
14
Deactivate password protection (GOTO 302)
4
Break off program/positioning
15
Activate password protection
(GOTO 270)
5
Acknowledge error
16
Deactivate password protection (GOTO 620)
6
Read current position as real null
17
Declare curve valid
7
Declare valid
18
Not-Stop with clear
8
Declare configuration valid
19
Not-Stop without clear
9
Traverse speed from external encoder
20
OBJECT_RSP temporarily enabled on PED
10
Drive under torque with opened brake
21
OBJECT_RSP temporarily disabled on PED
11
Drive dead with closed brake
22-24
Not assigned
Example
The drive must approach the machine zero point.
Service
Write request
Index
0x5fe9
Data byte
0x01
Command Code
0x8082
Sub-index
0
Param. counter
4
Length
1