2.7
Positioning
2.7.10
POS_FENSTER
37
2.7.10
POS_FENSTER
Positioning window.
The positioning window lies symmetrically around the target position.
Once the position actual value lies within this window, the Bit "Position reached" is set in the status word.
Object Description
Index
6067
Symbol
POS_FENSTER
Length
4
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned32
Access rights
Read/write all
PD Map
Not possible
Data Description
Unit
mm (or inch)
Resolution
1
⇔
0.001 mm (or inch)
Example
The positioning window is set to 15.000 mm.
Service
Write request
Sub-index
0
3. data byte
0x3a
Command Code
0x8082
Length
4
4. data byte
0x98
Param. counter
5
1. data byte
0x00
Index
0x6067
2. data byte
0x00
2.7.11
SCHLEPP_FEN
Contour error window.
The contour error window lies symmetrically around the currently set position set point.
If the current position indicator actual value lies outside this window, a contour error occurs.
Object Description
Index
0x6065
Symbol
SCHLEPP_FEN
Length
4
Access groups
0
Object code
Simple var.
Password
0
Data type
Unsigned32
Access rights
Read/write all
PD Map
Not possible
Data Description
Unit
mm (or inch)
Resolution
1
⇔
0.001 mm (or inch)
Example
The contour error window is set to 10.000 mm.
Service
Write request
Sub-index
0
3. data byte
0x27
Command Code
0x8082
Length
4
4. data byte
0x10
Param. counter
5
1. data byte
0x00
Index
0x6065
2. data byte
0x00
Содержание Hauser COMPAX-M Series