69
10 Overview: manufacturer-specific objects
10.1 Objects sorted by index
Command
Service
Index
Subind.
Byte
PDO
See page
Control byte
rd/wr
0x2000
0
1
R
Status byte
rd
0x2001
0
1
T
COMPAX control word
rd/wr
0x2002
0
2
R
COMPAX status word
rd
0x2003
0
2
T
Control commands
wr
0x2004
0
1
R
Command input in ASCII format
rd/wr
0x2005
0
20
-
Read/write parameters in binary format
rd/wr
0x2006
1...250
4
R
Settings for processing RPDO
rd/wr
0x200F
0
2
-
Current motor torque
rd
0x2010
0
2
T
Temperature of the power output stage
rd
0x2011
0
2
-
Control voltage and intermediate circuit voltage
rd
0x2012
1...2
2
-
Number of axis motion cycles
rd
0x2013
0
4
-
COMPAX operating hours
rd
0x2014
0
4
-
Loop counter for a running REPEAT loop
rd
0x2015
0
2
-
Status bits 1 and status bits 2.
rd
0x2016
1...2
1
-
Diagnosis values
rd
0x2017
1...4
1
-
Error message
rd
0x2018
1...2
1
-
Target position
rd
0x2020
0
4
-
Contour error
rd
0x2021
0
2
T
Position of the absolute value sensor
rd
0x2022
0
4
-
Set point speed and position default
wr
0x2023
0
6
R
Special commands for COMPAX XX70
wr
0x2024
1...6
4
-
Synchronization with automatic reverse travel
wr
0x2025
0
4
-
Synchronization without automatic reverse travel
wr
0x2026
0
4
-
Traverse speed
rd/wr
0x2030
0
2
R
Reduce traverse speed
rd/wr
0x2031
0
1
R
Change traverse speed
wr
0x2032
0
3
-
Speed step profile
wr
0x2033
0
8
-
Speed step profile with ACCEL
wr
0x2034
0
10
-
Current axis process speed
rd
0x2035
0
2
T
Mask inputs
rd/wr
0x2040
0
2
-
Mask outputs
rd/wr
0x2041
0
2
-
One digit. a digital output
wr
0x2042
1...16
1
-
Comparator function (active high)
wr
0x2043
1...16
4
-
Comparator function (active low)
wr
0x2044
1...16
4
-
Read/write program memory (binary)
rd/wr
0x2050
1...250
20
-
Set and read pointer
rd/wr
0x2051
0
1
-
Run program record N
wr
0x2052
0
1
R
Start program from record N
wr
0x2053
0
1
R
Transfer current position in record N
wr
0x2054
0
1
-
Set and read curve memory pointer
rd/wr
0x2055
0
2
-
Read and write curve memory
rd/wr
0x2056
0
3
-
Enter or read COMPAX variables
rd/wr
0x2057
1...40
4
R
Fault code
rd
0x603F
0
2
-
Control word
rd/wr
0x6040
0
2
R
Status word
rd
0x6041
0
2
T
Operation mode selection code
rd/wr
0x6060
0
2
-
Operation mode display
rd
0x6061
0
2
-
Position actual value
rd
0x6064
0
4
T