Control
Status word
31
Data Description
Bit
Assignment
Bit
Assignment
15
SPM
7
Reset fault
14
Approach machine zero (MZ)
6
Target position relative or absolute
13
START
5
12
Hand-
4
New set point
11
Hand+
3
Enable operation
10
reserved
2
Rapid stop
9
reserved
1
Disable voltage
8
STOP
0
Power on
6.9.8 Status word
Information about the status of the device as well as messages are displayed in the status word,
if SPM (status word) equals SPM (control word).
The status word displays pop-up messages, when SPM (status word) is not equal to SPM (control word).
Object Description
Index
0x6041
Symbol
STATUSWORT
Length
2
Min
0
Object code
Variable
Max
0xFFFF
Data type
Unsigned16
Access rights
read
PDO mapping
yes
Data Description
Bit
Assignment
Bit
Assignment
15
SPM
7
Warning
14
Idle after stop
6
Switch on disabled
13
MN was reached
5
Rapid stop
12
Actual value acknowledgment
4
Voltage disabled
11
Limit value
3
Fault
10
Set point reached
2
Operation enabled
9
Remote
1
Switched on
8
Ready for start
0
Ready to start
6.9.9 Pop-up message processing
COMPAX can generate the following pop-up message via the status word (if
P196Bit 0 = 1
):
#
an error has occurred.
#
the programmed set point has been reached.
#
the programmed comparator point has been reached.
The pop-up messages can be switched on (activated) individually via P193 (see page 68).
Pop-up message
Valency
automatic error message
1
automatic "position reached" message
2
automatic comparator switch points report
4