Object list
COMPAX CANopen
Control commands
32
"
"
"
"
The required settings can be obtained by inputting the sum of the significants in P193
If the pop-up message processing is active and there is a pop-up message, COMPAX interrupts the normal status display in
the status word, toggles the pop-up message flag "SPM" and displays the actual pop-up message in the status word.
The Master accepts the pop-up message and acknowledges it by toggling the "SPM" in the control word.
"
"
"
"
The status word displays a pop-up message, when SPM (status word) is not equal to SPM (control word).
Status word with pop-up messages
Bit
Assignment
Data byte [Bit]
Assignment
15
SPM
7
14
6
13
Pop-up message identifier
5
Error No.
12
4
or
11
1
=
error
3
Comparator No.
10
2
=
set point reached
2
9
3
=
Comparator point reached
1
8
0
6.9.10 Control commands
Compax commands not requiring any additional values.
The required commands are activated by reading in the relevant command number.
Object Description
Index
0x2004
Symbol
CONTROL
Length
1
Min
1
Object code
Variable
Max
19
Data type
Unsigned8
Access rights
write
PDO mapping
yes
Data Description
Comma
nd No.
Function
Comman
d No.
Function
1
Go to machine home
11
Drive dead with closed brake
2
Program start
12
Drive dead with opened brake
3
Stop program/positioning
13
Program jump via external inputs
4
Break off program/positioning
14
Deactivate password protection (GOTO 302)
5
Acknowledge error
15
Activate password protection(GOTO 270)
6
Read current position as real null
16
Deactivate password protection (GOTO 620)
7
Declare valid
17
Declare curve valid
8
Declare configuration valid
18
Not-Stop with clear
9
Traverse speed from external encoder
19
Not-Stop without clear
10
Drive under torque with opened brake
20-24
Not assigned