background image

Introduction

Follow these instructions when installing, operating, or servicing
the product.

Application Limits

These products are intended for use in general-purpose compressed
air systems only.

Operating Pressure:

kPa

PSIG

bar

Maximum Inlet Pressure

1035

150

10.0

Minimum Inlet Pressure

210

30

2.0

Ambient Temperature  Range:

  4°C to 54°C (40°F to 130°F)

Voltage Range:

Rated V10%, -15%

Symbol

Installation

The Solenoid Quick Exhaust

 

valves should be installed with

reasonable accessibility for service. Keep pipe or tubing lengths to
a minimum with inside clean and free of dirt and chips.  Pipe joint
compound should be used sparingly and applied only to the male
pipe – never into the female port.  Do not use PTFE tape to seal
pipe joints – pieces have a tendency to break off and lodge inside
the unit, possibly causing malfunction.  Care should be taken to
avoid undue strain on valve.

Air applied to the valve must be filtered with a 40 micron filter to
realize maximum component life.

!

 

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to

this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical

supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered

by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.

This document and other infor mation from The Company, its
subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning
the product or systems in the current product catalog. Due to the
variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to
change by The Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Life Expectancy

  -

 

Normal multi-million cycle life expectancy of

these valves is based on the use of properly filtered and lubricated
air at room temperature. These valves are also designed to operate
under non-lubricated conditions and will yield millions of maintenance
free cycles.

Factory Pre-Lubrication

 -

 

Valves are pre-lubricated at assembly

with a petroleum based grease which has a lithium content.

In-Service Lubrication

  -

 

In-service lubrication is not required;

however, if lubrication is to be used, F442 oil is recommended. This
oil is specially formulated to provide peak performance and
maximum service life from all air operated equipment. Otherwise,
use an air line lubricant (compatible with Nitrile & Polyurethane
seals) which will readily atomize and be of the medium aniline type.
Aniline point range must be between 180° and 220°F.
Viscosity at 100°F: 140 - 170 SUS.

!

CAUTION: Do not use synthetic, reconstituted, or oils with
an alcohol content or detergent additive.

!

CAUTION:

 

Do not restrict the inlet of valves having an

internal pilot supply. Pressure supply piping must be the
same size as the inlet port or larger to insure that the pilot
valve receives sufficient pressure supply during high flow
conditions.

Accessories

Kit No.

Description

Metal Mufflers

ES50MB 1/2"

Exhaust Muffler - S75

ES75MB 3/4"

Exhaust Muffler - S105

Plastic Mufflers

M60-04 1/2"

Exhaust Muffler - S75

M60-06 3/4"

Exhaust Muffler - S105

Function

The Solenoid Quick Exhaust valve is a 3-Port normally closed
3-Way, 2-Position directional control valve, which supplies
downstream pressure when the solenoid is energized.  Upon de-
energizing of the solenoid, the inlet air is blocked and the downstream
air is exhausted.  The bottom (exhaust) port is tapped 1/2” NPTF on
the S75 and 3/4” NPTF on the S105 so that the exhaust may be
piped away of fitted with a muffler.

Pneumatic Division

Richland, Michigan 49083
269-629-5000

Installation & Service Instructions
IS-S75/S105

Solenoid Quick Dump Valve
1/4", 3/8" & 1/2" S75 &
3/8", 1/2" & 3/4" S105

ISSUED:  February, 2005

Doc. #ISS75S105, ECN #050142, Rev. 1

Содержание F31

Страница 1: ...Service IS B35 Rev 3 B35 Integral Filter Regulator Installation Service IS B75 Rev 4 B75 Filter Regulator Installation Service IS B105 Rev 3 B105 Integral Filter Regulator Installation Service IS L35...

Страница 2: ...taining rod turns out of the body during disassembly the replacement element should be installed between the adapters as described above Ensure the gasket is assembled between the top adapter and the...

Страница 3: ...lement Bowl Hand Tighten Top Adapter Element Retaining Rod O Ring Manual Drain Finger Tighten Bottom Adapter Bowl Seal Body F51 Filter F101 Filter F31 Filter Filter Element Bowl Hand Tighten Bowl Guar...

Страница 4: ...an excessive pressure drop indicates cleaning is necessary Caution Filter bowl must be cleaned with household soap only WARNING To avoid unpredictable system behavior that can cause personal injury a...

Страница 5: ...OPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document and other information from The Company its subsidiaries and...

Страница 6: ...acement labels WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document...

Страница 7: ...e Manual drain filters must be drained regularly before the separated moisture and oil reaches the bottom of the lower baffle 2 The particulate Filter Element should be removed and replaced when press...

Страница 8: ...cessive pressure drop indicates cleaning is necessary Caution Filter bowl must be cleaned with household soap only WARNING To avoid unpredictable system behavior that can cause personal injury and pro...

Страница 9: ...op PSIG Pressure Drop bar 0 1 2 3 Primary Pressure PSIG 25 100 50 75 150 1 7 3 4 5 2 6 9 10 3 Primary Pressure bar Flow dm s 3 n Flow Characteristics F71 1 4 3 8 1 2 Inch Ports WARNING FAILURE OR IMPR...

Страница 10: ...d unpredictable system behavior that can cause personal injury and property damage Disconnect electrical supply when necessary before installation servicing or conversion Disconnect air supply and dep...

Страница 11: ...Internal Auto Drains RK602MD M4 Accessories Part Bowl Description Number Type Internal Automatic Drain Plastic R Option 175 PSI Max Pressure SA602MD B D Brass RX77 Option SA605MD B D Brass R Option 1...

Страница 12: ...n excessive pressure drop indicates cleaning is necessary Caution Filter bowl must be cleaned with household soap only WARNING To avoid unpredictable system behavior that can cause personal injury and...

Страница 13: ...ating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the final selection of the products and systems and assur...

Страница 14: ...r replacement labels WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This doc...

Страница 15: ...n model however manual draining can also be done by removing the bowl A visible coating of dirt or condensate on the filter element surface or an excessive pressure drop is an indication that cleaning...

Страница 16: ...ptions for further investigation by users having technical expertise It is important that you analyze all aspects of your application including consequences of any failure and review the information c...

Страница 17: ...t Return Spring Element Retainer and Element IMPORTANT The Filter Regulator will not operate properly if the Defector is not installed properly 9 Install Piston Assembly into Body Assembly Assemble Bo...

Страница 18: ...ct rupture can cause serious injury Do not connect regulator to bottled gas Do not exceed maximum primary pressure rating WARNING To avoid unpredictable system behavior that can cause personal injury...

Страница 19: ...3 16 18 UNEF 2B Installation All QUBE components are individually tapped NPT or BSPP to allow direct mounting to piping Also each FRL component comes equipped with the necessary screws and O rings to...

Страница 20: ...ocarbon based synthetic lubricants but before using check with the manufacturer of the lubricant or oil for compatibility with polyurethane resin TO CLEAN POLYURETHANE BOWLS USE MILD SOAP ANDWATER ONL...

Страница 21: ...Filter Element Poppet Assembly Poppet Return Spring 5 Clean and carefully inspect parts for wear or damage Wipe parts clean with soapy water or denatured alcohol but do not use denatured alcohol on pl...

Страница 22: ...uld not be covered by paint etc If masking is not possible contact your local representative for replacement labels WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS...

Страница 23: ...e torque is not required Turn on air supply if leakage occurs DO NOT OPERATE conduct repairs again The lubricator is now ready for setting 3 Oil delivery adjustment To adjust oil delivery turn Adjustm...

Страница 24: ...e serious injury Do not connect regulator to bottled gas Do not exceed maximum primary pressure rating WARNING To avoid unpredictable system behavior that can cause personal injury and property damage...

Страница 25: ...through the fill port a long spout oil can must be used Slowly remove fill plug and insert tip of spout to bottom of fill port recess or oil blow back will occur Fill to within 1 2 of top of bowl usin...

Страница 26: ...se Warnings and specifications on the product should not be covered by paint etc If masking is not possible contact your local representative for replacement labels WARNING FAILURE OR IMPROPER SELECTI...

Страница 27: ...nt knob is factory set so that when turned fully clockwise no oil is delivered to the venturi for atomization and equipment is not being lubricated To adjust oil drip rate turn on the air start flow a...

Страница 28: ...ted to this product before installation servicing or conversion Operate within the manufacturer s specified pressure temperature and other conditions listed in these instructions Medium must be moistu...

Страница 29: ...Then install Bonnet Assembly to Body and tighten to 4 5 to 5 6 Nm 40 to 50 in lb B Servicing the Poppet Assembly 1 Exhaust system media pressure as previously described Then remove Bottom Plug by uns...

Страница 30: ...matter This unit has DRYSEAL pipe threads use pipe compound or tape sparingly to male threads only Install units in pipeline so that flow is with the arrow as indicated on top face of body Install as...

Страница 31: ...PSI SPR 54 C Range 0 125 PSI SPR 55 Spacer Ring in Repair Kit R55 0081 Diaphragm Assembly Relieving in Kit RKR75 SAR75 0201 Non Relieving in Kit RKR75K SAR75 0202 Inner Valve Assembly in Repair Kit SA...

Страница 32: ...icing are subject to change by The Company and its subsidiaries at any time without notice EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT MAINTENANCE MANUALS THAT UTILIZE...

Страница 33: ...gulators Downstream pressure must be vented before servicing regulator Caution Grease packets are supplied with kits for lubrication of seals Use only mineral based grease or oils Do not use synthetic...

Страница 34: ...the information concerning the product or systems in the current product catalog Due to the variety of operating conditions and applications for these products or systems the user through its own anal...

Страница 35: ...olenoid Nut Finger Tight Cover Plunger Assembly Spring Body Bottom Spring Screw Torque 2 8 to 4 5 Nm 25 to 40 in lb U Cup O rings O ring 2 Gasket Disc Holder Assembly Bottom Plug Torque 4 5 to 6 8 Nm...

Страница 36: ...application including consequences of any failure and review the information concerning the product or systems in the current product catalog Due to the variety of operating conditions and applicatio...

Страница 37: ...Ground should be connected to the perpendicular terminal Use only connectors that comply with DIN 43650 Form B 11 mm blade spacing Override Operation The flush non locking manual override is located...

Страница 38: ...ones Note After servicing unit turn on air supply and check for leaks If leakage occurs do not operate conduct repairs and retest Note Items marked with an are included in the service kit 1 Remove the...

Страница 39: ...PTF or BSPP SC105 1 2 3 4 Inch NPTF or BSPP Pressure Temperature Ratings Solenoid 60 to 145 PSIG 4 1 to 10 0 bar 32 F to 140 F 0 C to 60 C Weight SC75 3 25 lb 1 47 kg SC105 5 5 lb 2 49 kg Materials of...

Страница 40: ...to the inlet port gradual filling of the downstream system occurs through the adjustable needle valve Upon reaching 70 of the supply pressure the valve switches from metered flow to full flow The ram...

Страница 41: ...uit Once the desired start up speed of the downstream circuit has been reached the adjustment area can be blocked off to prevent tampering by inserting the Lockout Pin provided in the package Any furt...

Страница 42: ...ntenance safety and warning requirements are met and that the application presents no health or safety hazards Complying with all existing warning labels and or providing all appropriate health and sa...

Страница 43: ...onents Air leakage Look and listen to see if there are any signs of visual damage to any of the components in the system Leakage is an indication of worn or damaged components Damaged or degraded comp...