3
Parker Hannifin
Pump and Motor Division
Trollhättan, Sweden
Service Manual
Series F02
Bulletin HY30-5519-M1/UK
Design and function
F2 is a piston pump with spherical pistons (1) inclu-
ding piston rings (2). The pistons are working at the
angle of 40° to the shaft (3). When the shaft rotates,
the pistons move up and down in the cylinder barrel
(4), forcing the oil to pass from the inlet port to the
outlet in the end cap (5). A ring gear (6) connects the
cylinder barrel to the drive shaft, causing these to
rotate at the same speed.
A barrel support (7) with a spring presses the cylinder
barrel against the end cap. An internal connection
from the housing to the suction port eliminates a se
-
parate drain line to the tank. F2 is provided with shaft
and connection flange that fits direct to PTO´s with ZF
standard.
Specifications
Frame size
F2-42/42
F2-53/53
F2-55/28
F2-70/35
F2-70/70
Displacement
(cm
3
/rev)
Port A
43
54
55
69
68
Port B
41
52
28
36
68
Max operating pressure
(bar)
intermittent
400
400
400
400
350
continuous
350
350
350
350
300
Max shaft speed
(rpm)
(unloaded pump; low pressure)
2550
2550
2550
2550
2550
Max selfpriming speed
(rpm)
Ports A
1)2)
and B
1)2)
pressurised
1800
1800
1800
1800
1650
Port A
2)
unloaded, pressure in port B
2100
2100
2100
2100
2100
Input power
(kW)
max intermittent
3)
100
126
100
126
131
max continuous
88
110
88
110
112
Weight
(kg)
19
19
19
19
19
1)
Valid with 2
1
/
2
" inlet (suction) line;
with 2" inlet line: 53/53 and 70/35 max 1100 rpm
42/42 and 55/28 max 1400 rpm. (q≈120l/min)
2)
Measured at 1.0 bar abs. inlet pressure.
Please note:
A lower inlet pressure affects pump performance.
3)
Max 6 seconds in any one minute.
1
2
5
6
7
3
4