![Parker F2 Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/parker/f2-series/f2-series_service-manual_756330005.webp)
5
Parker Hannifin
Pump and Motor Division
Trollhättan, Sweden
Service Manual
Series F02
Bulletin HY30-5519-M1/UK
Service Procedures
Exchange of shaft seals
A
B
C
D
1.
Pull out the outer seal ring A,e.g. by means of a screw
-
driver by piercing the wall of the seal. Take care not to
damage the sealing surface B of the shaft.
2.
Loosen the retaining ring C.
3.
Pull out the inner seal ring D in the same way as the
outer one.
4.
Check that the sealing surface of the shaft is undama
-
ged. If damaged, the pump has to be taken apart and
the slewe has to be replaced.
5.
Push on the new inner sealring.
6.
Fit the retaining ring. See to it, that the opening of the
retaining ring is placed at the indication hole, which will
otherwise be blocked.
7.
Fill out the space between retaining ring and shaft with
heat - resistant grease.
8.
Fit the new outer seal ring.