Mechanical Installation
NOTE
Refer to the Safety and EMC sheets provided with the drive.
Mount unit vertically inside a suitable cubicle. Drill mounting holes accurately.
Check for material that could damage/restrict operation.
•
Fit 4 x inserts into the back panel
•
Fit bolts/washers loosely into lower inserts
•
Engage the drive's lower mounting slots onto the bolts
•
Fit the top bolts and tighten - M6 : 4.5Nm (3.3 lbf.ft)
Ventilation
The Drive gives off heat during normal operation and requires:
•
Adequate cooling air to enter and exit the cubicle
•
Free flowing air through the drive's ventilation slots and heatsink
•
A normally cool mounting surface
•
Minimum air clearances to be maintained above and below drives and
other equipment (additive when two units are mounted together)
Overall Dimensions
Fixing Centres
Frame
Current Rating
(A)
Weight Kg (lbs)
Width
Height
Depth
Width
Height
Fixing
Air Clearance
(above/below)
1
35 - 70
10-14 (22-30) 250 (9.8) 415 (16.3) 171 (6.7)
200 (7.9)
400 (15.7)
M6
100/100mm
2
110 - 150
15 (33.2)
250 (9.8) 451 (17.8) 171 (6.7)
200 (7.9)
400 (15.7)
M6
100/100mm
3
180
17 (37.5)
250 (9.8) 485 (19.1) 213 (8.4)
200 (7.9)
400 (15.7)
M6
150/100mm
3
270
20 (44)
250 (9.8)* 485 (19.1) 213 (8.4)
200 (7.9)
400 (15.7)
M6
150/100mm
* Add 50 (1.9) for Power Terminals (6)
Dimensions are in millimetres (inches)
1 Keypad
4 P3 Port
7 Drive Earth/Ground
10 Status LEDs
2 Speed Feedback Option
5 Control Terminals
8 Exhaust (110A – 270A)
11 Field Terminals &
3 Communications Option
6 Power Terminals
9 Display
Auxiliary Power
1
2
11
7
3
4
5
6
6
6
8
9
10