412LXR Series Product Manual
Chapter 5 - Connecting the Drive / Amplifier
35
Gemini Adapter Cable
•
Use this cable to connect the Encoder and Hall Effect signals from an electrical panel strip to the
Gemini’s 26 pin Motor Feedback connector.
Function
Wire Color
Pin #
Encoder Wires
Ch A+
White
5
Ch A-
Yellow
6
Ch B+
Green
7
Ch B-
Blue
8
Ch Z+
Orange
9
Ch Z-
Brown
10
Ground
Black
3,4
+5 VDC
Red
1,2
Hall Signal Wires
Hall Gnd
White/Green
15
Hall +5V
White/Blue
14
Hall 1
White/Brown
16
Hall 2
White/Orange
17
Hall 3
White/Violet
18
Temperature Switch
Temp Switch
Yellow/Orange
12
Temp Switch
Yellow/Red
13
Shield
Yellow/Green
Shield Cover
Gemini Plug-in Connection Module
•
Use this module to directly connect the 412LXR’s Encoder and Hall Effect cables to the Gemini Drive.
Function
Wire Color
Pin #
Encoder Wires
Ch A+
White
5
Ch A-
Yellow
6
Ch B+
Green
7
Ch B-
Blue
8
Ch Z+
Orange
9
Ch Z-
Brown
10
Ground
Black
3,4
+5 VDC
Red
1,2
Shield
Green/Yellow
Shield Cover
Hall Signal Wires
Hall Gnd
White/Green
15
Hall +5V
White/Blue
14
Hall 1
White/Brown
16
Hall 2
White/Orange
17
Hall 3
White/Violet
18
Shield
Green/Yellow
Shield Cover
Temperature Switch
Temp Switch
Yellow
12
Temp Switch
Yellow
13
Gemini Motor Phase Connections
•
Use these Connections to connect the LXR’s Fork Terminal Motor Phase Cable to the Gemini Drive.
Function
Wire Color
Pin #
Motor Phase
Phase A
M.W. White #1
U
Phase B
M.W. White #1
V
Phase C
M.W. White #1
W
Ground
Green/Yellow
Grd
Shield
Shield
Shield Cover
PIN 1
PIN 14
PIN 26
PIN 13
Cable Length = 3 m
Daedal P/N 006-1683-01
Note: For Maximum Noise Immunity It is
recommended that the end of the Motor Cable be strip
back and connected to the Ground clamp located on
the side of the Gemini. See Gemini Hardware manual
for grounding details.