![Parker CM2115 Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/parker/cm2115/cm2115_user-manual_3889688081.webp)
User Guide
71
Summary of Test Results
Reverse Polarity - 12V/24V
ANSI/ASAE EP455_Feb_2008_Section 5.10.2
SAE J1455 _JUN_2006_section 4.13.1.1
SAE J1455 _JUN_2006_section 4.13.1.2
External Fuse
Short Circuit Protection - 12V/24V ANSI/ASAE EP455_Feb_2008_Section 5.10.4
Deviated: used 12V battery and 24V battery
Alternator Field Decay –
Power Leads – 12V
ANSI/ASAE EP455_Feb_2008 section 5.11.2
Deviated Rs=10
Ω
instead of 15
Ω
Positive Inductive Transient
Power Lines – 24V
ISO 7637-2_Jun/04 section 5.6.2_Pulse 2a at 100V
Inductive Load Switching
Power Lines – 24V
ISO 7637-2_Jun/04 section 5.6.1 Pulse 1 at -500V;
Deviated Rs=10
Ω
instead of 50
Ω
Mutual Coupling –12V / 24V
Coupling Clamp
ISO7637-3_Jan_2007 section 3.4.2 ± 300V
Transient Load Dump
SAE J1455_Jun2006 section 4.13.2.2.1
Accessory Noise – 24V
ANSI/ASAE EP455_Feb_2008_Section 5.11.1 at 27V
Batteryless Operation – 12V
ANSI/ASAE EP455_Feb_2008_Section 5.11.3
Cranking Waveform – 12V
ISO 7637-2_Jun/04 section 5.6.4
EMC – Emissions
ISO 14982/SAE J1113-41
Deviations: Used ANSI/ASAE EP455 Limit lines
EMC – Susceptibility
100 V/m at most frequencies (test equipment limitation)
ANSI/ASAE EP455_Feb_2008_Section 5.16.3
ISO 14982
SAE J1113-41
Electrostatic Discharge, Handling
& Operational
ANSI/ASAE EP455_Feb_2008_Section 5.12.2
Deviated: uncontrolled approach rate