![Parker CM2115 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/parker/cm2115/cm2115_user-manual_3889688045.webp)
User Guide
35
Outputs
6.1.4. 2.5 A High-Side Output with Current Sense
Capabilities
These outputs provide 2.5 A maximum continuous current with accurate current
sensing. The current sensing provides accurate readings to detect single load
disconnect on parallel driven load applications (i.e. when multiple loads are
driven by a single output). The current sensing can also be used for regulating
current control of hydraulic coils.
The following table provides specifications for the CM2115's 2.5 A high-side
outputs:
2.5 A High-Side Output with Current Sense Specifications
Item
MIN
NOM
MAX
UNIT
Switchable voltage range
6
-
32
V
Output current
0
-
2.5
A
Output on state resistance
-
45
-
m
Ω
Overvoltage -
-
36
V
PWM frequency
-
-
500
Hz
PWM resolution
-
0.1
-
%
Integrated flyback diode
-
Yes
-
-
Inductive pulse protection
-
-
628
V (peak)
Digital feedback negative going threshold
-
-
2.63
V
Digital feedback positive going threshold
2.80
-
-
V
Open load detection resistance
9.9k
10k
10.1k
Ω
Current
Sense
resistance
24.75 25 25.25
m
Ω
Current
Sense
gain
- 503 -
mV/A
Current Sense resolution
-
-
2.4
mA
Current Sense accuracy - Full Scale (2.5 A)
-
3
-
%
Leakage current
-
-
16
uA
Fixed Output Protection
The outputs have the following fixed protection mechanisms: