SECTION 3. INSTALLATION
17
Motor Connections
Motor connections are made via a 5-way spade terminal plug, mounted in the base of the drive.
The motor cable terminating plug is shown in Figure 3-3.
YELLOW (W)
WHITE (V)
BROWN (U)
GREEN (E)
E (NOT USED)
CAUTION - Risk of electric shock
HIGH VOLTAGES ARE PRESENT
ON THIS CONNECTOR (up to 400V peak)
Figure 3-3. Motor Connector
Motor Connector Pin
Functions
Signal Name
Lead Colour *
W
Yellow
V
White
U
Brown
E
Green
E
Not used
Table 3-3. Motor Connector Pin Functions
Rewiring the Motor Connections
The main motor cable has 5 leads and is terminated in a 5-way screw terminal connector. This
connector is easily removed and refitted where necessary. The lead colours are shown in Table
3-3; make a note of where each colour wire is connected before proceeding and take particular
care that the leads are reconnected correctly.
The cable used must have an insulation rating of greater than 1.35kV RMS.
Содержание BD-E Series