background image

HY10-1632-M2.1/US

Parker Hannifin Corporation

Accumulator & Cooler Division

United States

Installation & Disassembly

Bladder Accumulators

If you have questions about the information contained in 
this Maintenance & Installation Guide, please contact:

Accumulator & Cooler Division - Americas 

phone

 815 636 4100

parker.com/accumulator

The information specified in this guide serves to help 
understand how to install & maintain the product. The 
information given does not release the user from their 
own judgment and obligation of verification. The natural 
process of wear and aging also impacts how easily a 
product can be serviced.

Extra care is taken in the preparation of this literature, 
but Parker is not responsible for any inadvertent 
typographical errors or omissions. Information in this 
guide is only accurate as of the date of this publication. 
For a more current information base, please consult the 
Parker Accumulator & Cooler Division website at: 

www.parker.com/accumulator 

Machesney Park, Illinois

10711 N. Second Street, Machesney Park, Il 61115

© Copyright 2016 Parker Hannifin Corporation. All rights reserved.

Santa Fe Springs, California

14087 Borate Street, Santa Fe Springs, CA 90670

WARNING - USER RESPONSIBILITY

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS 
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product 
or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely 
responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, 
safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable  
industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided 
from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide 
component or system options based upon data or specifications provided by the user, the user is responsible for determining that such 
data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

!

Offer of Sale

The items described in this document are hereby 
offered for sale by Parker Hannifin Corporation, its 
subsidiaries or its authorized distributors. This offer 
and its acceptance are governed by the provisions 
in the “Offer of Sale.”

Содержание BA Series

Страница 1: ...Installation Disassembly Bladder Accumulators Electronic Catalog HY10 1632 M2 1 US ...

Страница 2: ...N OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document and other information from Parker Hannifin Corporation its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise The user through its own analysis and testing is solely responsible fo...

Страница 3: ... the buyer to maintain and service the accumulator at regular intervals General Information The following safety instructions must always be followed when working with hydraulic accumulators Only use an inert gas like nitrogen for a pre charging Nitrogen that is 99 99 percent by volume is strongly recommended Do not use oxygen or shop air as this may lead to a fire or explosion Modifying a bladder...

Страница 4: ...N AND ITS AFFILIATES PARKER MAY NOT BE COPIED OR DISCLOSED TO OTHERS OR USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER AND MUST BE RETURNED OR DESTROYED AND ALL FURTHER USE DISCONTINUED AT PARKER S REQUEST THE RECIPIENT OF THIS DOCUMENT IS ADVISED THAT IMPROPER SELECTION OR IMPROPER USE OF PARKER SYSTEMS OR COMPONENTS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE AND IS SOLE...

Страница 5: ...S WITH PARKER AND MUST BE RETURNED OR DESTROYED AND ALL FURTHER USE DISCONTINUED AT PARKER S REQUEST THE RECIPIENT OF THIS DOCUMENT IS ADVISED THAT IMPROPER SELECTION OR IMPROPER USE OF PARKER SYSTEMS OR COMPONENTS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE AND IS SOLELY RESPONSIBLE THROUGH ITS OWN ANALYSIS AND TESTING FOR THE FINAL SELECTION OF PARKER SYSTEM AND COMPONENTS AND ASSURING T...

Страница 6: ...Spanner wrench Core repair tool and Core installation tool Figure 2 Typical rounded edge flathead screwdriver or ball head hex Clean Inspect Cleaning All metal parts should be cleaned with a cleaning agent Seals and soft parts should be wiped clean Bladder Item 2 Inflate bladder to normal size Wash bladder with a soap solution If soap solution bubbles discard bladder After testing deflate bladder ...

Страница 7: ...re 6 Remove hex jam nut Item 5 from bladder valve stem Item 2 Prevent valve stem from twisting with an appropriate wrench applied to the valve stem flats Figure 7 Fold bladder Item 2 and pull out of accumulator shell Item 1 A slight twisting motion while pulling on the bladder reduces effort required to remove bladder from shell If bladder is slippery hold with a cloth Assembly Disassembly Figure ...

Страница 8: ...luid to lubricate and cushion the bladder Item 2 Make sure the entire inside of the shell is lubricated Figure 9 Insert the bladder pull rod 085109xxxx through both the shell s valve stem opening and fluid port opening Attach the bladder pull rod to the bladder valve stem Item 26 Figure 10 With all gas completely exhausted from bladder Item 2 collapse bladder and fold longitudinally in a compact r...

Страница 9: ...e stem from twisting with an appropriate wrench applied to the valve stem flats Torque jam nut to proper torque based on accumulator size per the Suggested Approximate Torque Values on page 2 of this guide Figure 11 Once the bladder valve stem has been pulled through the valve stem opening in the shell install the valve stem hex nut Item 5 by hand Once the valve stem hex nut is in place remove the...

Страница 10: ...ving the bladder from either the hydraulic end or the gas end of the accumulator Clean Inspect Cleaning All metal parts should be cleaned with a cleaning agent Seals and soft parts should be wiped clean Bladder Item 2 Inflate bladder to normal size Wash bladder with a soap solution If soap solution bubbles discard bladder After testing deflate bladder immediately Hydraulic Port Assembly Item 7 Ins...

Страница 11: ...ill accumulator with approximately 50 PSI nitrogen This will hold the gas end adapter in place 8 Install the metal backup Item 18 o ring Item 14 and o ring backup Item 16 9 Install the outer spacer Item 10 10 Install the outer locking ring Item 8 Hydraulic Port Assembly Installation 1 Holding the hydraulic port assembly Item 7 by the threaded end insert the poppet end into the shell fluid port Lay...

Страница 12: ...e 17 Install O ring Item 14 over hydraulic port assembly Item 7 and push it using a blunt rounded edge flathead screw driver or a ball head hex into the shell s fluid port until it bottoms out against the washer CAUTION Do not twist or damage o ring 7 Install O ring backup Item 16 over hydraulic port assembly Item 7 and push until it bottoms against O ring Item 14 1 40 gallon sizes and 5K only 8 F...

Страница 13: ...umulator capacity This fluid will act as a cushion when the accumulator is pre charged with gas 12 Pre charge accumulator to desired pressure See pre charge instructions 13 Install accumulator on machine 9 Figure 19 Install the locking ring Item 8 on the hydraulic port assembly Item 7 Using a spanner wrench 0851100000 tighten securely per the Suggested Approximate Torque Values on page 3 of this g...

Страница 14: ...emove bleeder plug Item 21 if the accumulator is equipped with one on hydraulic port assembly Figure 3 Using a spanner wrench 0851100000 remove lock ring Item 8 from the hydraulic port assembly Item 7 use an adjustable wrench on the flats located on the port assembly to prevent port assembly from rotating Remove spacer Item 10 then push the hydraulic port assembly Item 7 into the shell Item 1 prio...

Страница 15: ...2 1 US 10 2016 2016 Parker Hannifin Corporation Parker Hannifin Corporation Accumulator Cooler Division 10711 N Second Street Machesney Park IL 61115 phone 815 636 4100 fax 815 636 4111 www parker com accumulator ...