HY10-1632-M2.1/US
Parker Hannifin Corporation
Accumulator & Cooler Division
United States
Installation & Disassembly
Bladder Accumulators
2
Accumulator Parts Description (Gas Side)
Parts Description
Bill of Material for Figures A-E
Item No.
Description
1
Shell
2
Bladder and Stem Assembly
3
O-Ring / Sealing Washer
4
Gas Valve Core
5
Hex Jam Nut
6
Protective Cap
7
Hydraulic Port Assembly
8
Hex Jam Nut /Locking Ring
10
Hydraulic Port Spacer
12
Anti-Extrusion Ring
14
O-Ring
16
Backup Ring
18
Backup Washer (Metal)
25
Backup Ring (2" Stem Only)
26
Gas Valve
27
O-Ring (2" Stem Only)
29
Gas Valve Cap
Suggested Approximate Torque Values
Item No.
Description
Torque (English)
Torque
(Metric)
4
Gas Valve Core
3-5 In-Lb
0.34-0.56 N-M
5
Hex Jam Nut (10-150 Cu. In.)
10-15 Ft-Lb
14-20 N-M
5
Hex Jam Nut (1-15 Gallon)
100-120 Ft-Lb
136-163 N-M
6
Protective Cap
10-15 Ft-Lb
14-20 N-M
8
Locking Ring (1 Gallon)
100 Ft-Lb (Min)
136 N-M (Min)
8
Locking Ring (2.5-15 Gallon)
500 Ft-Lb (Min)
678 N-M (Min)
26
Gas Valve (All Styles)
22-28 Ft-Lb
30-38 N-M
29
Gas Valve Cap
12-24 In-Lb
1-3 N-M
1
1
2
2
3
3
4
4
A
A
B
B
C
C
D
D
DRAWING NUMBER
MODEL / PART NUMBER
APPROVED BY
DRAWN BY
DRAWN MM/DD/YYYY
WEIGHT
PARKER HANNIFIN CORPORATION
ACCUMULATOR & COOLER DIVISION
MACHESNEY PARK, IL 61115, USA
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS: IN [MM], WEIGHTS: LB [KG]
TOLERANCES: .XX [.XXX] = ±.01 [0.254]
.XXX [.XXXX] = ±.005 [0.1270]
ANGLES = ±2°
SURFACE FINISH: 125
µ
IN [3.2
µ
M] RMS
BREAK EDGES: R.005-.015 [0.1270-0.3810]
DO NOT SCALE DRAWING
THIS DOCUMENT AND THE INFORMATION IT CONTAINS IS CONFIDENTIAL AND
PROPRIETARY TO PARKER-HANNIFIN CORPORATION AND ITS AFFILIATES
("PARKER"), MAY NOT BE COPIED OR DISCLOSED TO OTHERS OR USED FOR
ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND MUST
BE RETURNED OR DESTROYED AND ALL FURTHER USE DISCONTINUED AT
PARKER'S REQUEST. THE RECIPIENT OF THIS DOCUMENT IS ADVISED THAT
IMPROPER SELECTION OR IMPROPER USE OF PARKER SYSTEMS OR
COMPONENTS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE, AND IS SOLELY RESPONSIBLE THROUGH ITS OWN ANALYSIS AND
TESTING FOR THE FINAL SELECTION OF PARKER SYSTEM AND COMPONENTS
AND ASSURING THAT ALL PERFORMANCE, ENDURANCE, MAINTENANCE,
SAFETY AND WARNING REQUIREMENTS OF THE INTENDED APPLICATION ARE
MET. COPYRIGHT PARKER ©. YEAR OF COPYRIGHT IS THE YEAR(S) INDICATED
ON THIS DOCUMENT. ALL RIGHTS RESERVED.
ECR CHANGE DESCRIPTION
ECR NUMBER
ECR MM/DD/YYYY
CHECKED BY
SKC406266
N/A
VIEWS FOR BLADDER MAINTENANCE MANUAL & CATALOG
SHEET 1 (GAS VALVE END)
SHEET 2 (HYDRAULIC PORT END)
04/19/2016
JPK
A
SHEET 1 OF 2
REV
REFERENCE
THIRD ANGLE PROJECTION
INCH [METRIC]
MATERIAL
2
5
4
3
6
2
5
26
3
6
2
23
12
5
18
14
16
10
8
2
23
12
5
18
14
16
10
8
6
26
5
25
27
2
29
FIGURE A
3-4 KPSI, 330 Bar
10 Cu. In. – 150 Cu. In.
BOTTOM REPAIRABLE
FIGURE B
3-3.6 KPSI, 330 Bar
1-15 GALLON
BOTTOM REPAIRABLE
FIGURE C
3-3.6 KPSI, 330 Bar
2.5-15 GALLON
TOP REPAIRABLE
FIGURE D
5-6.6 KPSI, 690 Bar
2.5-15 GALLON
TOP REPAIRABLE
FIGURE E
5-6.6 KPSI, 690 Bar
1-15 GALLON
BOTTOM REPAIRABLE
(ITEMS # 25 & 27 DO NOT APPLY
ON 1 GALLON UNITS)
1
1
1
1
1
26
3
6
26
29
6
FIGURE A
3-4 KPSI, 330 Bar
10-150 Cu. In.
Bottom Repairable
FIGURE B
3-3.6 KPSI, 330 Bar
1-15 Gallon
Bottom Repairable
FIGURE C
3-3.6 KPSI, 330 Bar
2.5-15 Gallon
Top Repairable
FIGURE D
5-6.6 KPSI, 690 Bar
2.5-15 Gallon
Top Repairable
FIGURE E
5-6.6 KPSI, 690 Bar
1-15 Gallon
Bottom Repairable
(Items #25 & 27 Do Not Apply)